Compare reported gap fits across four pressure conditions, with original units and source locations.
Cs(V0.93Nb0.07)3Sb5 · Transverse-field μSR · 10 mT. These are fits to measured data, reported at four applied hydrostatic pressures.
Tc is a parameter of the gap-structure fit. The separate AC susceptibility measurements used zero-field conditions.
| Parameter | 0 GPa | 0.4 GPa | 0.8 GPa | 1.2 GPa |
|---|---|---|---|---|
| λ⁻²(T = 0) (μm⁻²)Inverse squared London penetration depth | 6.9(3) | 5.7(3) | 10.0(4) | 12.5(1) |
| λ(T > 0) (nm)London penetration depth | 381 | 419 | 315 | 283 |
| ωPhase fraction in the gap fit | 1 | 1 | 0.73(4) | 1 |
| Tc (K)Transition temperature from gap-structure fit | 3.000(6) | 3.25(1) | 6.67(7) | 6.94(2) |
| Δ₁ (meV)First gap parameter | 0.54(9) | 0.47(7) | 0.65(5) | 1.56(4) |
| Δ₂ (meV)Second gap parameter | Not listed (source dash) | Not listed (source dash) | 3.5(9) | Not listed (source dash) |
The table retains λ(T > 0) and λ⁻²(T = 0) as printed. λ denotes London penetration depth. Parenthetical uncertainties are unchanged; unlisted Δ₂ cells are source dashes.
ω is the phase fraction in this fit, as defined by the authors. It is not a measured superconducting volume fraction.
| Parameter | 0 GPa | 0.4 GPa | 0.8 GPa | 1.2 GPa |
|---|---|---|---|---|
| χ²Fit statistic | 4.5 | 2.6 | 15.4 | 34.8 |
| χ²/NDFFit statistic per degree of freedom | 0.346 | 0.153 | 1.1 | 1.74 |
χ² and χ²/NDF describe the authors’ fits. They are not SCLib acceptance scores; no threshold or rescaling has been applied.
The ambient prose reports Tc = 4.70(3) K, λ = 316(5) nm and Δ = 0.590(5) meV. This is a separate fit from the table’s 0 GPa column.
Compare the original observation windowsarXiv:2411.18744v1, captured 5 October 2026. HTML Table 1 and PDF Table I (page 8) were checked for these values and units. Publication status and equivalence to catalogue ingestion remain unverified.
The paper states a single-crystal default unless otherwise specified. Table 1 has no unique physical specimen identifier. Its pressure labels do not establish an absolute/gauge convention, and 0 GPa is not a conversion of ambient wording.
The ambient prose and pressure-table fits have unresolved dataset and specimen correspondence. These source readings are unassociated with a selected catalogue result. Independent human review, scientific acceptance and formal property promotion remain separate.
JSON includes exact cell and row-label HTML character ranges, element IDs and SHA-256 hashes. Offsets count Unicode code points and exclude the end position. Source dashes and uncertainty strings are retained without normalization.
HTML SHA-256: b5f1bc07212429562d977e9def108dbbc075e86977ab6d54e5ea597cd3bacf53
PDF SHA-256: bddff2c5fbac870cbebdadec91d4fc14687081b97cc72aa10f80834eb2c94f99