Estimation of superconducting cavity bandwidth and detuning using a Luenberger observer
Bozo Richter, Andrea Bellandi, Julien Branlard, Leon Speidel, Annika Eichler
DOI 10.1103/48zw-grdp · Physical Review Accelerators and Beams
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
Enabled by progress in superconducting technology, several continuous wave linear accelerators are foreseen in the next decade. For these machines, it is of crucial importance to track the main cavity parameters, such as the resonator bandwidth and detuning. The bandwidth yields information on the superconducting state of the cavity. The detuning should be minimized to limit the required power for operation of the cavity. The estimation of these parameters is commonly implemented in the digital electronics of the low-level rf control system to minimize the computation delay. In this proceedings paper, we present a way to compute the bandwidth and detuning using a Luenberger observer. In contrast to previous methods, the state observer yields estimations at the native control system sample rate without explicitly filtering the input signals. Additionally, the error convergence properties of the estimations can be controlled intuitively by adjusting gain parameters. Implementation considerations and test results for the derived observer are presented in the manuscript.
Similar papers
Application of disturbance observer-based control on pulsed superconducting radio frequency cavities
similarity 0.85Feng Qiu et al.
Source status unknown — claims are unverified
Resonant Coupling Parameter Estimation with Superconducting Qubits
similarity 0.84J.H. Béjanin et al.
Source status unknown — claims are unverified
Digital base-band rf control system for the superconducting Darmstadt electron linear accelerator
similarity 0.83M. Konrad et al.
Source status unknown — claims are unverified
Measurement scheme for the Lamb shift in a superconducting circuit with broadband environment
similarity 0.83V. Gramich et al.
Source status unknown — claims are unverified
High precision superconducting cavity diagnostics with higher order mode measurements
similarity 0.82Stephen Molloy et al.
Source status unknown — claims are unverified
Calibrating magnetic flux control in superconducting circuits by compensating distortions on timescales from nanoseconds up to tens of microseconds
similarity 0.82Christoph Hellings et al.
Source status unknown — claims are unverified