Photon-number resolution with microwave Josephson photomultipliers
E. V. Stolyarov, O. V. Kliushnichenko, V. S. Kovtoniuk, A. A. Semenov
DOI 10.1103/PhysRevA.108.063710 · Physical Review A
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
We study counting photons confined in a mode of a microwave resonator via repeated measurements by a Josephson photomultiplier (JPM). The considered JPM is essentially a flux-biased phase qubit operating as a single-photon detector. We identify optimal operational regimes that maximize photon-number resolution within a predetermined range. Two counting techniques are studied. The first is to count the total number of clicks in the measurement sequence. The second involves counting the number of clicks until the occurrence of either the first no-click event or the end of the measurement sequence. Our theoretical methods employ the derived positive operator-valued measures for the considered photocounting techniques and the introduced measure of the photon-number resolution. The results reveal that the resolution decrease in both cases is mainly caused by the JPM relaxation. As an example, we show how the obtained results can be used for practical testing nonclassical properties of electromagnetic radiation in a microwave resonator.
Similar papers
Measuring weak microwave signals via current-biased Josephson junctions: Approaching the quantum limit of energy detection
similarity 0.89Y. Q. Chai et al.
Source status unknown — claims are unverified
Characterizing quantum microwave radiation and its entanglement with superconducting qubits using linear detectors
similarity 0.88C. Eichler et al.
Source status unknown — claims are unverified
Quantum cavity modes in spatially extended Josephson systems
similarity 0.87M. V. Fistul & A. V. Ustinov
Source status unknown — claims are unverified
Bistability in a mesoscopic Josephson junction array resonator
similarity 0.87P. R. Muppalla et al.
Source status unknown — claims are unverified
Temporal array with superconducting nanowire single-photon detectors for photon-number resolution
similarity 0.87Mattias Jönsson et al.
Source status unknown — claims are unverified
Flux qubit-based detector of microwave photons
similarity 0.86O. A. Ilinskaya et al. · 2024 · arXiv:2402.07801
Source status unknown — claims are unverified