Ultimate bunch length and emittance performance of an MeV ultrafast electron diffraction apparatus with a dc gun and a multicavity superconducting rf linac
A. Bartnik, C. Gulliford, G. H. Hoffstaetter, J. Maxson
DOI 10.1103/PhysRevAccelBeams.25.093401 · Physical Review Accelerators and Beams
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
We present the design of a high repetition rate MeV energy ultrafast electron diffraction instrument based on a dc photoelectron gun and an superconducting rf (SRF) linac with multiple independently controlled accelerating and bunching cavities. The design is based on the existing Cornell photoinjector, which can readily be applied to the presented findings. Using particle tracking simulations in conjunction with multiobjective genetic algorithm optimization, we explore the smallest bunch lengths, emittance, and probe spot sizes achievable. We present results for both stroboscopic conditions (with single electrons per pulse) and with 105 electrons/bunch which may be suitable for single-shot diffraction images. In the stroboscopic case, the flexibility provided by the many-cavity bunching and acceleration allows for longitudinal phase space linearization without a higher harmonic field, providing sub-fs bunch lengths at the sample. Given low emittance photoemission conditions, these small bunch lengths can be maintained with probe transverse sizes at the single micron scale and below. In the case of 105 electrons per pulse, we simulate state-of-the-art 5D brightness conditions: rms bunch lengths of 10 fs with 3-nm normalized emittances, while now permitting repetition rates as high as 1.3 GHz. Finally, to aid in the design of new SRF-based ultrafast electron diffraction machines, we simulate the trade-off between the number of cavities used and achievable bunch length and emittance.
Similar papers
High-brightness megahertz-rate beam from a direct-current and superconducting radio-frequency combined photocathode gun
similarity 0.86H. Jia et al.
Source status unknown — claims are unverified
High-Brightness Continuous-Wave Electron Beams from Superconducting Radio-Frequency Photoemission Gun
similarity 0.85I. Petrushina et al.
Source status unknown — claims are unverified
Systematic study of multipactor suppression techniques for a superconducting rf gun
similarity 0.84Eden Tafa Tulu et al.
Source status unknown — claims are unverified
Overview on superconducting photoinjectors
similarity 0.83A. Arnold & J. Teichert
Source status unknown — claims are unverified
Development of a prototype superconducting radio-frequency cavity for conduction-cooled accelerators
similarity 0.82G. Ciovati et al. · 2023 · arXiv:2302.07201
Source status unknown — claims are unverified
Systematical study on superconducting radio frequency elliptic cavity shapes applicable to future high energy accelerators and energy recovery linacs
similarity 0.82Valery Shemelin et al.
Source status unknown — claims are unverified