A three-junction SQUID-on-tip with tunable in-plane and out-of-plane magnetic field sensitivity
Yonathan Anahory, Jonathan Reiner, Lior Embon, Dorri Halbertal, Anton Yakovenko, Yuri Myasoedov, Michael L. Rappaport, Martin E. Huber, Eli Zeldov
arXiv:1410.1609 · DOI 10.1021/nl503022q · 2014-10-07 · Nano letters
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
Nanoscale superconducting quantum interference devices (SQUIDs) demonstrate record sensitivities to small magnetic moments, but are typically sensitive only to the field component that is normal to the plane of the SQUID and out-of-plane with respect to the scanned surface. We report on a nanoscale three-junction Pb SQUID which is fabricated on the apex of a sharp tip. Because of its three-dimensional structure, it exhibits a unique tunable sensitivity to both in-plane and out-of-plane fields. We analyze the two-dimensional interference pattern from both numerical and experimental points of view. This device is integrated into a scanning microscope and its ability to independently measure the different components of the magnetic field with outstanding spin sensitivity better than $5\ \frac{μ_B}{\mathrm{Hz}^{1/2}}$ is demonstrated. This highlights its potential as a local probe of nanoscale magnetic structures.
Similar papers
Multi-terminal multi-junction dc SQUID for nanoscale magnetometry
similarity 0.90Alexander Y. Meltzer et al. · 2016 · arXiv:1606.05682
Source status unknown — claims are unverified
Quantum analysis of a nonlinear microwave cavity-embedded dc SQUID displacement detector
similarity 0.87P. D. Nation et al. · 2008 · arXiv:0806.4171
Source status unknown — claims are unverified
Displacement Detection with a Vibrating RF SQUID: Beating the Standard Linear Limit
similarity 0.87Eyal Buks et al. · 2007 · arXiv:0705.0206
Source status unknown — claims are unverified
Dispersive magnetometry with a quantum limited SQUID parametric amplifier
similarity 0.87M. Hatridge et al. · 2010 · arXiv:1003.2466
Source status unknown — claims are unverified
Dual on-chip SQUID measurement protocol for flux detection in large magnetic fields
similarity 0.86Josiah Cochran et al. · 2020 · arXiv:2012.07559
Source status unknown — claims are unverified
Amplitude and frequency sensing of microwave fields with a superconducting transmon qudit
similarity 0.85Maximilian Kristen et al. · 2019 · arXiv:1908.09556
Source status unknown — claims are unverified