Abstract
Hysteretic losses in MgB2 wound superconducting coils of a 500 kW synchronous hybrid generator were estimated as part of the European project SUPRAPOWER led by the Spanish company Tecnalia Research and Innovation. Particular interest was given to the losses found in tapes in the superconducting rotor caused by the magnetic flux ripples originating from the conventional stator during nominal operation. To compute the losses, a 2D Finite Element Method was applied to solve the H-formulation of Maxwell's equations considering the nonlinear properties of both the superconducting material and its surrounding Ni matrix. To be able to model all the different turns composing the winding of the superconducting rotor coils, three geometrical models of single tape cross section of decreasing complexity were studied: 1) the first model reproduced closely the actual cross section obtained from micrographs, 2) the second model was obtained from the computed elastoplastic deformation of a round Ni wire, 3) the last model was based on a simplified elliptic cross section. The last geometry allowed validating the modeling technique by comparing numerical losses with results from well-established analytical expressions. Additionally, the following cases of filament transpositions were studied: no, partial and full transposition. Finally, choosing the right level of geometrical details to predict the expected behavior of individual superconducting tapes in the rotor, the following operational regimes were studied: Bias-DC current, ramping current under ramping background field, and magnetic flux ripples under DC background current and field.
Similar papers
Estimation of hysteretic losses in the HTS coils made of coated conductor tapes of an electric generator during transient operation
similarity 0.89Zermeño, Víctor M. R. et al. · 2016 · arXiv:1601.06830
Source status unknown — claims are unverified
Local electromagnetic properties and hysteresis losses in Non-Uniformly wound 2G-HTS Racetrack Coils
similarity 0.86B. C. Robert et al. · 2019 · arXiv:1907.09893
Source status unknown — claims are unverified
Influence of Coil Position on AC Losses of Stator Superconducting Windings of a Synchronous Machine for a 10 MW Wind Turbine
similarity 0.85Carlos Roberto Vargas-Llanos et al. · 2021 · arXiv:2102.12278
Source status unknown — claims are unverified
T-A Formulation to Model Electrical Machines with HTS Coated Conductor Coils
similarity 0.85Tara Benkel et al. · 2019 · arXiv:1901.02370
Source status unknown — claims are unverified
Calculation of AC losses in stacks and coils made of second generation high temperature superconducting tapes for large scale applications
similarity 0.85Victor M. R. Zermeno et al. · 2013 · arXiv:1308.2568
Source status unknown — claims are unverified
Finite-element simulations of hysteretic ac losses in a magnetically coated superconducting tubular wire subject to an oscillating transverse magnetic field
similarity 0.85Y. A. Genenko et al. · 2015 · arXiv:1506.01804
Source status unknown — claims are unverified