Experimental and theoretical study of AC losses in variable asymmetrical magnetic environments
S. T. Ranecky, H. Watanabe, J. Ogawa, T. Oka, D. Goelden, L. Alff, Y. A. Genenko
arXiv:1705.05193 · DOI 10.1088/1361-6668/aa73bc · 2017-05-15 · Superconductor Science and Technology
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
Measurements of AC losses in a HTS-tape placed in between of two bulk magnetic shields of high permeability were performed by applying calorimetric techniques for various asymmetrical shielding arrangements. The experiment was supported by analytical calculations and finite-element simulations of the field and current distributions, based on the Bean model of the critical state. The simulated current and field profiles perfectly reproduce the analytic solutions known for certain shielding geometries. The evaluation of the consequent AC losses exhibits good agreement with measurements for the central position of the tape between the magnets but increasing discrepancy when the tape is approaching the shields. This can be explained by the increasing contribution of the eddy currents and magnetic hysteresis losses in the conducting shields.
Similar papers
Theoretical analysis of the transport critical-state ac loss in arrays of superconducting rectangular strips
similarity 0.87Enric Pardo et al.
Source status unknown — claims are unverified
Theoretical and experimental study of AC loss in HTS single pancake coils
similarity 0.87J. Šouc et al. · 2008 · arXiv:0808.0061
Source status unknown — claims are unverified
Numerical evaluation of AC losses in an HTS insert coil for high field magnet during its energization
similarity 0.86K. Kajikawa et al. · 2014 · arXiv:1405.7765
Source status unknown — claims are unverified
Strong reduction of ac losses in a superconductor strip located between superconducting ground plates
similarity 0.86Yu. A. Genenko · 2003 · arXiv:cond-mat/0307234
Source status unknown — claims are unverified
Integral Equations for Computing AC Losses of Radially and Polygonally Arranged HTS Thin Tapes
similarity 0.86Roberto Brambilla et al. · 2013 · arXiv:1306.6006
Source status unknown — claims are unverified
Three-dimensional electromagnetic modeling of practical superconductors for power applications
similarity 0.85M Kapolka · 2016 · arXiv:1605.09610
Source status unknown — claims are unverified