Optimized proximity thermometer for ultrasensitive detection: Role of an ohmic electromagnetic environment

Danilo Nikolić, Bayan Karimi, Diego Subero Rengel, Jukka P. Pekola, Wolfgang Belzig

arXiv:2303.06059 · DOI 10.1103/PhysRevB.108.024507 · 2023-03-10 · Physical Review B

T1experimental1 citations

Active bibliographic source — not scientific approval

Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.

Abstract

We propose a mesoscopic thermometer for ultrasensitive detection based on the proximity effect in superconductor-normal metal (SN) heterostructures. The device is based on the zero-bias anomaly due to the inelastic Cooper pair tunneling in an SNIS junction (I stands for an insulator) coupled to an ohmic electromagnetic (EM) environment. The theoretical model is done in the framework of the quasiclassical Usadel Green's formalism and the dynamical Coulomb blockade. The usage of an ohmic EM environment makes the thermometer highly sensitive down to very low temperatures, $T \lesssim 5~$mK. Moreover, defined in this way, the thermometer is stable against small but nonvanishing voltage amplitudes typically used for measuring the zero-bias differential conductance in experiments. Finally, we propose a simplified view, based on an analytic treatment, which is in very good agreement with numerical results and can serve as a tool for the development, calibration, and optimization of such devices in future experiments in quantum calorimetry.

Source-reported materials — not catalogue approval

FormulaReported Tc (K)Pressure (GPa)Type
Al

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

1.3Pressure not reportedunknown