Decrease of Ac Losses in High Tc Superconducting Tapes by Application of a DC Current
Benoit des Ligneris, Marcel Aubin, Julian Cave, When Zhu, Patricia Dolez
arXiv:cond-mat/9907271 · 1999-07-19 · arXiv: Superconductivity
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
The ac losses in a silver-gold alloy sheathed Bi-2223 tape were measured by the null calorimetric method while a dc current was superimposed onto the ac current. As expected through computer simulations, a Clem valley was observed for the larger ac currents. A reduction of ac losses of approximately 50% at the valley minimum is observed in accord with the calculations. At lower ac currents, the data fit the calculated behavior with a single parameter, a Meissner current of 21.8 A. It is shown that a surface barrier current is incompatible with the data.
Source-reported materials — not catalogue approval
| Formula | Reported Tc (K) | Pressure (GPa) | Type |
|---|---|---|---|
| NbTi Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | — | Pressure not reported | unknown |
Similar papers
Electromagnetic modelling of superconductors with a smooth current-voltage relation: variational principle and coils from a few turns to large magnets
similarity 0.89Enric Pardo et al. · 2014 · arXiv:1410.0772
Source status unknown — claims are unverified
Effect of combining a DC bias current with an AC transport current on AC losses in a High Temperature Superconductor
similarity 0.87Patricia Dolez et al. · 1998 · arXiv:cond-mat/9811269
Source status unknown — claims are unverified
Effects of impurities on Hc2(T) in superconductors without inversion symmetry
similarity 0.87K. V. Samokhin · 2008 · arXiv:0807.4951
Source status unknown — claims are unverified
Magneto-optical investigations of Ag-sheathed Bi-2223 tapes with ferromagnetic shielding
similarity 0.86V. V. Yurchenko et al. · 2006 · arXiv:cond-mat/0607065
Source status unknown — claims are unverified
Numerical evaluation of AC losses in an HTS insert coil for high field magnet during its energization
similarity 0.85K. Kajikawa et al. · 2014 · arXiv:1405.7765
Source status unknown — claims are unverified
Temperature- and Field Dependent Characterization of a Twisted Stacked-Tape Cable
similarity 0.85Christian Barth et al. · 2015 · arXiv:1502.06728
Source status unknown — claims are unverified