← Back to search

Detection of Coherent Terahertz Radiation from a High-Temperature Superconductor Josephson Junction by a Semiconductor Quantum-Dot Detector

R. Shaikhaidarov, V. N. Antonov, A. Casey, A. Kalaboukhov, S. Kubatkin, Y. Harada, K. Onomitsu, A. Tzalenchuk, A. Sobolev

DOI 10.1103/PhysRevApplied.5.024010 · Physical Review Applied

T1

Active bibliographic source — not scientific approval

Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.

Abstract

We examine the application of Josephson radiation emitters to spectral calibration of single-photon-resolving detectors. Josephson junctions are patterned in a YBCO film on a bicrystal sapphire substrate and are voltage controlled to generate radiation in the frequency range of 0.05–1 THz. The detector used in this work consists of a gate-defined quantum-dot photon-to-charge transducer coupled to a single-electron transistor. Both the emitter and the detector are equipped with a matching on-chip wide-band antenna. The combination of a tuneable emitter and detector allows us to determine the efficacy of the YBCO emitter and also to analyze the elementary processes involved in the detection.

Source-reported materials — not catalogue approval

FormulaReported Tc (K)Pressure (GPa)Type
YBCO

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

—Pressure not reportedunknown
Bi2Sr2CaCu2O8

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

—Pressure not reportedunknown