Effect of Higher-Order Nonlinearities on Amplification and Squeezing in Josephson Parametric Amplifiers
Samuel Boutin, David M. Toyli, Aditya V. Venkatramani, Andrew W. Eddins, Irfan Siddiqi, Alexandre Blais
DOI 10.1103/PhysRevApplied.8.054030 · Physical Review Applied
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
Single-mode Josephson-junction-based parametric amplifiers are often modeled as perfect amplifiers and squeezers. We show that in practice, the gain, quantum efficiency, and output field squeezing of these devices are limited by usually neglected higher-order corrections to the idealized model. To arrive at this result, we derive the leading corrections to the lumped-element Josephson parametric amplifier of three common pumping schemes: monochromatic current pump, bichromatic current pump, and monochromatic flux pump. We show that the leading correction for the last two schemes is a single Kerr-type quartic term, while the first scheme contains additional cubic terms. In all cases, we find that the corrections are detrimental to squeezing. In addition, we show that the Kerr correction leads to a strongly phase-dependent reduction of the quantum efficiency of a phase-sensitive measurement. Finally, we quantify the departure from the ideal Gaussian character of the filtered output field from numerical calculation of third- and fourth-order cumulants. Our results show that while a Gaussian output field is expected for an ideal Josephson parametric amplifier, higher-order corrections lead to non-Gaussian effects which increase with both gain and nonlinearity strength. This theoretical study is complemented by experimental characterization of the output field of a flux-driven Josephson parametric amplifier. In addition to a measurement of the squeezing level of the filtered output field, the Husimi Q function of the output field is imaged by the use of a deconvolution technique and compared to numerical results. This work establishes nonlinear corrections to the standard degenerate parametric amplifier model as an important contribution to the Josephson parametric amplifier’s squeezing and noise performance.
Similar papers
Higher-order nonlinear effects in a Josephson parametric amplifier
similarity 0.91Bogdan A. Kochetov & Arkady Fedorov
Source status unknown — claims are unverified
Optimal Operation of a Josephson Parametric Amplifier for Vacuum Squeezing
similarity 0.90M. Malnou et al.
Source status unknown — claims are unverified
Optimizing Josephson-ring-modulator-based Josephson parametric amplifiers via full Hamiltonian control
similarity 0.89Chenxu Liu et al.
Source status unknown — claims are unverified
Squeezing Limit of the Josephson Ring Modulator as a Nondegenerate Parametric Amplifier
similarity 0.89Dong Hwan Kim et al.
Source status unknown — claims are unverified
Quantum-limited parametric amplification with Josephson circuits in the regime of pump depletion
similarity 0.89Ananda Roy & Michel Devoret
Source status unknown — claims are unverified
Observation of parametric amplification and deamplification in a Josephson parametric amplifier
similarity 0.88B. Yurke et al.
Source status unknown — claims are unverified