Hysteretic ac losses in a superconductor strip between flat magnetic shields
Yu. A. Genenko, H. Rauh
arXiv:0912.3432 · DOI 10.1088/0953-2048/23/7/075007 · 2009-12-17
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
Hysteretic ac losses in a thin, current-carrying superconductor strip located between two flat magnetic shields of infinite permeability are calculated using Bean's model of the critical state. For the shields oriented parallel to the plane of the strip, penetration of the self-induced magnetic field is enhanced, and the current dependence of the ac loss resembles that in an isolated superconductor slab, whereas for the shields oriented perpendicular to the plane of the strip, penetration of the self-induced magnetic field is impaired, and the current dependence of the ac loss is similar to that in a superconductor strip flanked by two parallel superconducting shields. Thus, hysteretic ac losses can strongly augment or, respectively, wane when the shields approach the strip.
Similar papers
AC losses in superconducting composite strips in a magnetic field in the form of a standing wave
similarity 0.92V. Sokolovsky & V. Meerovich · 2005 · arXiv:cond-mat/0512656
Source status unknown — claims are unverified
Experimental and theoretical study of AC losses in variable asymmetrical magnetic environments
similarity 0.90S. T. Ranecky et al. · 2017 · arXiv:1705.05193
Source status unknown — claims are unverified
Overcritical states of a superconductor strip in a magnetic environment
similarity 0.90Yu. A. Genenko et al.
Source status unknown — claims are unverified
Hysteretic ac loss of superconducting strips simultaneously exposed to ac transport current and phase-different ac magnetic field
similarity 0.89Yasunori Mawatari & Kazuhiro Kajikawa · 2006 · arXiv:cond-mat/0612072
Source status unknown — claims are unverified
Strong reduction of ac losses in a superconductor strip located between superconducting ground plates
similarity 0.89Yu. A. Genenko · 2003 · arXiv:cond-mat/0307234
Source status unknown — claims are unverified
Finite-element simulations of hysteretic ac losses in a magnetically coated superconducting tubular wire subject to an oscillating transverse magnetic field
similarity 0.89Y. A. Genenko et al. · 2015 · arXiv:1506.01804
Source status unknown — claims are unverified