Time-division SQUID multiplexers with reduced sensitivity to external magnetic fields
G. M. Stiehl, H. M. Cho, G. C. Hilton, K. D. Irwin, J. A. B. Mates, C. D. Reintsema, B. L. Zink
arXiv:1008.5106 · DOI 10.1109/TASC.2010.2091483 · 2010-08-30 · IEEE Transactions on Applied Superconductivity
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
Time-division SQUID multiplexers are used in many applications that require exquisite control of systematic error. One potential source of systematic error is the pickup of external magnetic fields in the multiplexer. We present measurements of the field sensitivity figure of merit, effective area, for both the first stage and second stage SQUID amplifiers in three NIST SQUID multiplexer designs. These designs include a new variety with improved gradiometry that significantly reduces the effective area of both the first and second stage SQUID amplifiers.
Similar papers
Anomalous Frequency Noise from the Megahertz Channelizing Resonators in Frequency-Division Multiplexed Transition Edge Sensor Readout
similarity 0.86John Groh et al. · 2020 · arXiv:2012.07077
Source status unknown — claims are unverified
Quantum interference in asymmetric superconducting nanowire loops
similarity 0.85J. Hudis et al. · 2022 · arXiv:2203.17199
Source status unknown — claims are unverified
Grooved Dayem nanobridges as building blocks of high-performance YBaCuO SQUID magnetometers
similarity 0.84Edoardo Trabaldo et al. · 2019 · arXiv:1903.07511
Source status unknown — claims are unverified
Development of 2D Bi-SQUID Arrays with High Linearity
similarity 0.84S. Berggren et al. · 2013 · arXiv:1301.2163
Source status unknown — claims are unverified
Flux ramp modulation based MHz frequency-division dc-SQUID multiplexer
similarity 0.84Daniel Richter et al. · 2021 · arXiv:2101.06424
Source status unknown — claims are unverified
Development of a microwave SQUID multiplexer for magnetic microbolometers
similarity 0.84N. Müller et al. · 2025 · arXiv:2509.23507
Source status unknown — claims are unverified