The superconducting proposal for the CS magnet system of FAST: a preliminary analysis of the heat load due to AC losses
N. Pompeo, L. Muzzi
arXiv:1101.5825 · 2011-01-30 · arXiv: Instrumentation and Detectors
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
FAST (Fusion Advanced Studies Torus), the Italian proposal of a Satellite Facility to ITER, is a compact tokamak (R$_0$ = 1.82 m, a = 0.64 m, triangularity $δ$ = 0.4) able to investigate non-linear dynamics effects of $α$-particle behavior in burning plasmas and to test technical solutions for the first wall/divertor directly relevant for ITER and DEMO. Currently, ENEA is investigating the feasibility of a superconducting solution for the magnet system. This paper focuses on the analysis of the CS (Central Solenoid) magnet thermal behavior. In particular, considering a superconducting solution for the CS which uses the room available in the resistive design and referring to one of the most severe scenario envisaged for FAST, the heat load of the CS winding pack due to AC losses is preliminarily evaluated. The results provide a tentative baseline for the definition of the strand requirements and conductor design, that can be accepted in order to fulfil the design requirements.
Similar papers
Critical State Theory For The Magnetic Coupling Between Soft Ferromagnetic Materials And Type-II Superconductors
similarity 0.85M. U. Fareed & H. S. Ruiz · 2021 · arXiv:2109.02604
Source status unknown — claims are unverified
A Note on the Stability of Cable-in-Conduit Conductors with Current Dependent Power-Law Index
similarity 0.85A. Anghel · 2013 · arXiv:1304.4812
Source status unknown — claims are unverified
Current distribution and ac loss for a superconducting rectangular strip with in phase alternating current and applied field
similarity 0.85E. Pardo et al. · 2005 · arXiv:cond-mat/0510314
Source status unknown — claims are unverified
2D Modeling of HTS Coils with - Formulation: How to Handle Different Coupling Scenarios
similarity 0.85Bárbara Maria Oliveira Santos et al. · 2022 · arXiv:2202.02014
Source status unknown — claims are unverified
Practical Forecasting of AC Losses in Multi-layer 2G-HTS Cold Dielectric Conductors
similarity 0.85M. Clegg & H. S. Ruiz · 2022 · arXiv:2210.11345
Source status unknown — claims are unverified
Review of the AC Loss Computation for HTS using the H-formulation
similarity 0.85Boyang Shen et al. · 2019 · arXiv:1908.02176
Source status unknown — claims are unverified