Practical Forecasting of AC Losses in Multi-layer 2G-HTS Cold Dielectric Conductors
M. Clegg, H. S. Ruiz
arXiv:2210.11345 · DOI 10.1109/TASC.2023.3257275 · 2022-10-20 · IEEE Transactions on Applied Superconductivity
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
With the recent progresses on the designing and manufacturing of lightweight and high engineering current density superconducting cables, the need for an established, fast, and sufficiently accurate computational model for the forecasting of AC-losses in cold-dielectric conductors, is pivotal for increasing the investment confidence of power grid operators. However, validating such models is not an easy task, this because on the one hand, there is a low availability of experimental results for large scale power cables and, on the other hand, there is a large number of 2G-HTS tapes involved whose cross-sectional aspect ratio hinders the numerical convergence of the models within reasonable delivery times. Thus, aiming to overcome this challenge, we present a detailed two-dimensional H-model capable to reproduce the experimentally measured AC-losses of multi-layer power cables made of tens of 2G-HTS tapes. Two cable designs with very high critical currents have been considered, the first rated at 1.7 kA critical current, consisting of fifty 4 mm width 2G-HTS tapes, these split in 5 concentric layers wound over a cylindrical former, with the three inner layers forming an arrangement of 24 tapes shielded by two further layers with 13 tapes each. This cable is contrasted with a size wise equivalent cable with 67 superconducting tapes rated at 3.2 kA critical current, whose design implies the use of 40 tapes of 3 mm width split within four core layers, and 27 tapes of 4 mm width distributed in two shielding layers. In both situations a remarkable resemblance between the simulations and experiments has been found, rendering to acceptable estimates of the AC-losses for cold dielectric conductors, and offering a unique view of the local electrodynamics of the wound tapes where the mechanisms of shielding, magnetization, and transport currents can coexist within the hysteretic process.
Similar papers
Electromagnetic Assessment and AC Losses of Triaxial Cables with Multiple 2G-HTS Layers Per Phase
similarity 0.88M. Clegg & H. S. Ruiz · 2022 · arXiv:2210.11361
Source status unknown — claims are unverified
Computational Modelling of Russia's First 2G-HTS Triaxial Cable
similarity 0.87M. Clegg et al. · 2022 · arXiv:2201.08892
Source status unknown — claims are unverified
Modelling the mechanics of 32 T REBCO superconductor magnet using numerical simulation
similarity 0.87Arpit Kumar Srivastava & Enric Pardo · 2024 · arXiv:2401.01266
Source status unknown — claims are unverified
Local electromagnetic properties and hysteresis losses in Non-Uniformly wound 2G-HTS Racetrack Coils
similarity 0.87B. C. Robert et al. · 2019 · arXiv:1907.09893
Source status unknown — claims are unverified
Implementation of the H- formulation in COMSOL Multiphysics for simulating the magnetization of bulk superconductors and comparison with the H-formulation
similarity 0.86Alexandre Arsenault et al. · 2020 · arXiv:2006.13784
Source status unknown — claims are unverified
Finite-element simulations of hysteretic ac losses in a magnetically coated superconducting tubular wire subject to an oscillating transverse magnetic field
similarity 0.86Y. A. Genenko et al. · 2015 · arXiv:1506.01804
Source status unknown — claims are unverified