Abstract
For an accurate estimation of the AC losses of superconducting triaxial cables, we present a 2D model capable to provide a global assessment of multi-layer triaxial cables, validated against the AC-losses on single-phase cables provided by the VNIIKP Cable Institute. Four models are presented, the first being a single-phase cable of 50 tapes and the others being three triaxial cables made of up to 135 coated conductors distributed in up to 9 layers. A systematic study is devised, where the number of layers per phase increases from 1 to 3, with at least 14 tapes distributed across each layer of the first (innermost) phase, 15 in the secondary (middle) phase, and 16 in the third (outermost) phase, respectively. Remarkably, our results reveal that the simple strategy of considering an unbalanced distribution for the amplitudes of the applied current, can generally balance the magnetic field between the three phases even for the bilayer and trilayer cables, resulting in negligible magnetic leaks in all situations. Besides, our simulations allow to see for the first time how the transport and magnetization currents distribute across the thickness of all the superconducting tapes, from which we have found that the AC-losses of the 2nd phase is generally higher than at the other phases at low to moderate transport currents Itr < 0.8 Ic. Nevertheless, depending on whether the Ic of the SC tapes at the 3rd phase layers is lower than the one at the 2nd phase, the layers at the third phase can exhibit a considerable increment on the AC losses, as result of the considered magneto angular anisotropy of the HTS tapes, which lead to intriguing electromagnetic features that suggest a practical threshold for the applied transport current, being it 0.8 Ic. Likewise, the relative change in the AC-losses per adding layers, per phase, and as a function of the applied current is disclosed.
Similar papers
- formulation in Sparselizard combined with domain decomposition methods for modeling superconducting tapes, stacks, and twisted wires
similarity 0.88Nicolo Riva et al. · 2022 · arXiv:2212.03274
Source status unknown — claims are unverified
Finite-element simulations of hysteretic ac losses in a magnetically coated superconducting tubular wire subject to an oscillating transverse magnetic field
similarity 0.88Y. A. Genenko et al. · 2015 · arXiv:1506.01804
Source status unknown — claims are unverified
Review of the AC Loss Computation for HTS using the H-formulation
similarity 0.88Boyang Shen et al. · 2019 · arXiv:1908.02176
Source status unknown — claims are unverified
Computational Modelling of Russia's First 2G-HTS Triaxial Cable
similarity 0.88M. Clegg et al. · 2022 · arXiv:2201.08892
Source status unknown — claims are unverified
Practical Forecasting of AC Losses in Multi-layer 2G-HTS Cold Dielectric Conductors
similarity 0.88M. Clegg & H. S. Ruiz · 2022 · arXiv:2210.11345
Source status unknown — claims are unverified
Implementation of the H- formulation in COMSOL Multiphysics for simulating the magnetization of bulk superconductors and comparison with the H-formulation
similarity 0.87Alexandre Arsenault et al. · 2020 · arXiv:2006.13784
Source status unknown — claims are unverified