In-situ Broadband Cryogenic Calibration for Two-port Superconducting Microwave Resonators
Jen-Hao Yeh, Steven M. Anlage
arXiv:1212.4427 · DOI 10.1063/1.4797461 · 2012-12-18 · The Review of scientific instruments
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
We introduce an improved microwave calibration method for use in a cryogenic environment, based on a traditional three-standard calibration, the Thru-Reflect-Line (TRL) calibration. The modified calibration method takes advantage of additional information from multiple measurements of an ensemble of realizations of a superconducting resonator, as a new pseudo-Open standard, to correct errors in the TRL calibration. We also demonstrate an experimental realization of this in-situ broadband cryogenic calibration system utilizing cryogenic switches. All calibration measurements are done in the same thermal cycle as the measurement of the resonator (requiring only an additional 20 minutes), thus avoiding 4 additional thermal cycles for traditional TRL calibration (which would require an additional 12 days). The experimental measurements on a wave-chaotic microwave billiard verify that the new method significantly improves the measured scattering matrix of a high-quality-factor superconducting resonator.
Similar papers
Experimental Demonstration of a Superconductor SFQ-Based ADC for High-Frequency Signal Acquisition
similarity 0.87Beyza Zeynep Ucpinar et al. · 2025 · arXiv:2510.14191
Source status unknown — claims are unverified
Role of non-linear effects and standing waves in microwave spectroscopy: Corbino measurements on superconductors and VO
similarity 0.85Mario Zinßer et al. · 2018 · arXiv:1810.07784
Source status unknown — claims are unverified
Cryogenic Microwave Filter Cavity with a Tunability Greater than 5 GHz
similarity 0.85T. J. Clark et al. · 2018 · arXiv:1810.02404
Source status unknown — claims are unverified
Efficient Superconductor Arithmetic Logic Unit for Ultra-Fast Computing
similarity 0.85Sasan Razmkhah & Ali Bozbey · 2023 · arXiv:2312.09386
Source status unknown — claims are unverified
Sample-based calibration for cryogenic broadband microwave reflectometry measurements
similarity 0.85F. Couëdo et al. · 2018 · arXiv:1801.00436
Source status unknown — claims are unverified
Superconducting atomic contacts inductively coupled to a microwave resonator
similarity 0.85C. Janvier et al. · 2014 · arXiv:1409.8065
Source status unknown — claims are unverified