Superconducting flux-flow type ultra-low-noise magnetic sensors - An alternative to dc-SQUIDs
Roberto Monaco, Carmine Granata, Roberto Russo, antonio Vettoliere
arXiv:1304.5761 · 2013-04-21 · arXiv: Mesoscale and Nanoscale Physics
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
A superconducting magnetometers based on the magnetic field dependence of the Eck step voltage in long Josephson tunnel junctions (LJTJs) is demonstrated. The field to be measured is applied perpendicular to a continuous superconducting pickup loop. Wherever the loop has a narrow constriction, the density of the flux-restoring circulating currents will become relatively high and will locally create a magnetic field large enough to bring a biased LJTJ in the flux-flow state, i.e., at a finite voltage proportional to the field strength. This method allows the realization of a novel family of robust and general-purpose superconducting devices which, despite their simplicity, function as ultra-low-noise, wide-band and high-dynamics magnetometers. The performances of low-T$_c$ sensor prototypes, among which a highly linear voltage responsivity and a magnetic spectral density $S_B^{1/2}< 3\,fT/Hz^{1/2}$, promise to be competitive with those of the best superconducting quantum interference devices.
Similar papers
Long Josephson Tunnel Junctions with Doubly Connected Electrodes
similarity 0.90Roberto Monaco et al. · 2011 · arXiv:1112.1265
Source status unknown — claims are unverified
Hybrid superconducting quantum magnetometer
similarity 0.90F. Giazotto & F. Taddei · 2011 · arXiv:1103.3598
Source status unknown — claims are unverified
High performance magnetic field sensor based on Superconducting Quantum Interference Filters
similarity 0.89P. Caputo et al. · 2004 · arXiv:cond-mat/0404646
Source status unknown — claims are unverified
Influence of resonances on the noise performance of SQUID susceptometers
similarity 0.89Samantha I Davis et al. · 2019 · arXiv:1911.03836
Source status unknown — claims are unverified
Andreev spin-noise detector
similarity 0.89Roberto Capecelatro et al. · 2023 · arXiv:2308.01995
Source status unknown — claims are unverified
Ultra linear magnetic flux-to-voltage conversion in superconducting quantum interference proximity transistors
similarity 0.89Giorgio De Simoni & Francesco Giazotto · 2022 · arXiv:2207.00339
Source status unknown — claims are unverified