In the past few years there has been a significant rise in the short-circuit current levels in transmission and distribution networks, it due to the increasing demands on power and the addition of sources of distributed generations. It leads to the need of integration of novel protection systems such as the superconducting fault current limiters (SFCLs), ... . SFCL models on the electric distribution networks largely rely on the insertion of a step or exponential resistance that is determined by a predefined quenching time. However, beyond the framework of these models, the study of the performance, reliability, and location strategy for the installation of sole or multiple SFCLs in power grids still lacks of proper development leading to the utter need of comprehensive and systematic studies on this issue. In this paper, we expand the scope of the aforementioned models by considering the actual behaviour of a SFCL in terms of the temperature dynamic power-law dependence between the electrical field and the current density. Our results are compared with step-resistance models for the sake of discussion and clarity of the conclusions. Both SFCL models were integrated into a power system model built based on the UK power standard, and the impact of these protection strategies on the performance of the overall electricity network was studied. As a representative renewable energy source, a 90 MVA wind farm was considered for the simulations. Three fault conditions have been simulated, and the figures for the fault current reduction predicted by both fault current limiting models have been compared in terms of multiple current measuring points and allocation strategies...
Similar papers
Transient stability of a power system with superconducting fault current limiters
similarity 0.86V. Sokolovsky et al. · 2007 · arXiv:cond-mat/0701308
Source status unknown — claims are unverified
Current density distribution in resistive fault current limiters and its effect on device stability
similarity 0.84Mohammad Farokhiyan et al. · 2020 · arXiv:2003.01399
Source status unknown — claims are unverified
Superconducting phase transition in inhomogeneous chains of superconducting islands
similarity 0.83Eduard Ilin et al. · 2020 · arXiv:2011.02997
Source status unknown — claims are unverified
Temperature and phase dynamics in superconducting weak-link
similarity 0.83Anjan K. Gupta et al. · 2014 · arXiv:1408.5223
Source status unknown — claims are unverified
Field-free superconducting diode in a magnetically nanostructured superconductor
similarity 0.83Ji Jiang et al. · 2022 · arXiv:2208.02078
Source status unknown — claims are unverified
Stability of power-law cable-in-conduit superconductors
similarity 0.82A. Anghel · 2004 · arXiv:cond-mat/0402044
Source status unknown — claims are unverified