Tiny adiabatic-demagnetization refrigerator for a commercial superconducting quantum interference device magnetometer
Taku J Sato, Daisuke Okuyama, Hideo Kimura
arXiv:1612.01376 · DOI 10.1063/1.4972249 · 2016-12-02 · The Review of scientific instruments
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
A tiny adiabatic-demagnetization refrigerator (T-ADR) has been developed for a commercial superconducting quantum interference device magnetometer [Magnetic Property Measurement System (MPMS) from Quantum Design]. The whole T-ADR system is fit in a cylindrical space of the diameter $8.5$ mm and the length $250$ mm, and can be inserted into the narrow sample tube of MPMS. A sorption pump is self-contained in T-ADR, and hence no complex gas handling system is necessary. With the single crystalline Gd$_3$Ga$_5$O$_{12}$ garnet ($\sim 2$ grams) used as a magnetic refrigerant, the routinely achievable lowest temperature is $\sim 0.56$ K. The lower detection limit for a magnetization anomaly is $\sim 1 \times 10^{-7}$ emu, estimated from fluctuation of the measured magnetization. The background level is $\sim 5 \times 10^{-5}$ emu below 2 K at $H = 100$ Oe, which is largely attributable to a contaminating paramagnetic signal from the magnetic refrigerant.
Source-reported materials — not catalogue approval
| Formula | Reported Tc (K) | Pressure (GPa) | Type |
|---|---|---|---|
| Zn Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | — | Pressure unresolved | midpoint |
Similar papers
Competition of magnetism and superconductivity in underdoped (Ba1-xKx)Fe2As2
similarity 0.86Marianne Rotter et al. · 2008 · arXiv:0812.2827
Source status unknown — claims are unverified
Real-space probing of the local magnetic response of thin-film superconductors using single spin magnetometry
similarity 0.85D. Rohner et al. · 2018 · arXiv:1807.07584
Source status unknown — claims are unverified
A nuclear magnetic resonance spectrometer for operation around 1 MHz with a sub 10 mK noise temperature based on a two stage dc SQUID
similarity 0.85L. V. Levitin et al. · 2007 · arXiv:0710.4367
Source status unknown — claims are unverified
Efficient electronic cooling above 2 K by niobium-based superconducting tunnel junctions
similarity 0.85J. Hätinen et al. · 2024 · arXiv:2403.08655
Source status unknown — claims are unverified
Experimental evidence for bulk superconductivity in pure Bismuth single crystal at ambient pressure
similarity 0.84Om Prakash et al. · 2016 · arXiv:1603.04310
Source status unknown — claims are unverified
Cryogen-free variable temperature scanning SQUID microscope
similarity 0.84Logan Bishop-Van Horn et al. · 2018 · arXiv:1812.03215
Source status unknown — claims are unverified