A micro-SQUID with dispersive readout for magnetic scanning microscopy
Farshad Foroughi, Jan-Michael Mol, Tristan Mueller, John R. Kirtley, Kathryn A. Moler, Hendrik Bluhm
arXiv:1803.07636 · DOI 10.1063/1.5030489 · 2018-03-20 · Applied Physics Letters
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
We have designed and characterized a micro-SQUID with dispersive readout for use in low temperature scanning probe microscopy systems. The design features a capacitively shunted RF SQUID with a tunable resonance frequency from 5 to 12 GHz, micrometer spatial resolution and integrated superconducting coils for local application of magnetic fields. The SQUID is operated as a nonlinear oscillator with a flux- and power-dependent resonance frequency. Measurements for device characterization and noise benchmarking were carried out at 4 K. The measured flux noise above 10 kHz at 4 K is $80\;\mathrm{n}Φ_0 \mathrm{Hz}^{-1/2}$ at a bandwidth of 200 MHz. Estimations suggest that one can benefit from parametric gain based on inherent nonlinearity of the Josephson junction and reduce the flux noise to $30\;\mathrm{n}Φ_0\mathrm{Hz}^{-1/2}$ at 100 mK, which corresponds to $7.5\;\mathrm{μ_B Hz^{-1/2}}$ for a magnetic moment located at the center of the pickup loop.
Similar papers
Nanoscale multifunctional sensor formed by a Ni nanotube and a scanning Nb nanoSQUID
similarity 0.91J. Nagel et al. · 2013 · arXiv:1305.1195
Source status unknown — claims are unverified
Superconducting microwave magnetometer for absolute flux detection
similarity 0.91Simon Günzler et al. · 2021 · arXiv:2107.05929
Source status unknown — claims are unverified
Advanced SQUID-on-lever scanning probe for high-sensitivity magnetic microscopy with sub-100-nm spatial resolution
similarity 0.90Timur Weber et al. · 2025 · arXiv:2508.01927
Source status unknown — claims are unverified
Micro-SQUID characteristics
similarity 0.90K. Hasselbach et al. · 2001 · arXiv:cond-mat/0110517
Source status unknown — claims are unverified
Stochastic resonance in thermally bistable Josephson weak-links and micro-SQUIDs
similarity 0.90Sagar Paul et al. · 2020 · arXiv:2010.13349
Source status unknown — claims are unverified
Scanning nano-SQUID with single electron spin sensitivity
similarity 0.90Denis Vasyukov et al. · 2013 · arXiv:1308.0694
Source status unknown — claims are unverified