Practical tests of neutron transmission imaging with a superconducting kinetic-inductance sensor
The Dang Vu, Hiroaki Shishido, Kazuya Aizawa, Kenji M. Kojima, Tomio Koyama, Kenichi Oikawa, Masahide Harada, Takayuki Oku, Kazuhiko Soyama, Shigeyuki Miyajima, Mutsuo Hidaka, Soh Y. Suzuki, Manobu M. Tanakai, Alex Malins, Masahiko Machida, Shuichi Kawamata, Takekazu Ishida
arXiv:2105.03612 · DOI 10.1016/J.NIMA.2021.165411 · 2021-05-08 · Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
Samples were examined using a superconducting (Nb) neutron imaging system employing a delay-line technique which in previous studies was shown to have high spatial resolution. We found excellent correspondence between neutron transmission and scanning electron microscope (SEM) images of Gd islands with sizes between 15 and 130 micrometer which were thermally-sprayed onto a Si substrate. Neutron transmission images could be used to identify tiny voids in a thermally-sprayed continuous Gd2O3 film on a Si substrate which could not be seen in SEM images. We also found that neutron transmission images revealed pattern formations, mosaic features and co-existing dendritic phases in Wood's metal samples with constituent elements Bi, Pb, Sn and Cd. These results demonstrate the merits of the current-biased kinetic inductance detector (CB-KID) system for practical studies in materials science. Moreover, we found that operating the detector at a more optimal temperature (7.9 K) appreciably improved the effective detection efficiency when compared to previous studies conducted at 4 K. This is because the effective size of hot-spots in the superconducting meanderline planes increases with temperature, which makes particle detections more likely.
Similar papers
Thermoelectric radiation detector based on superconductor/ferromagnet systems
similarity 0.82T. T. Heikkilä et al. · 2017 · arXiv:1709.08856
Source status unknown — claims are unverified
Low kinetic inductance superconducting nanowire photon detectors with a 100 picosecond relaxation time
similarity 0.82Sergey Cherednichenko et al. · 2019 · arXiv:1911.01480
Source status unknown — claims are unverified
Highly Multiplexible Thermal Kinetic Inductance Detectors for X-Ray Imaging Spectroscopy
similarity 0.81Gerhard Ulbricht et al. · 2015 · arXiv:1506.07537
Source status unknown — claims are unverified
Impact of Gd doping on morphology and superconductivity of NbN sputtered thin films
similarity 0.81Rajveer Jha et al. · 2013 · arXiv:1303.1614
Source status unknown — claims are unverified
Critical Temperature tuning of Ti/TiN multilayer films suitable for low temperature detectors
similarity 0.80A. Giachero et al. · 2013 · arXiv:1307.3781
Source status unknown — claims are unverified
Tunable sub-gap radiation detection with superconducting resonators
similarity 0.80O. Dupré et al. · 2018 · arXiv:1802.10379
Source status unknown — claims are unverified