Highly Multiplexible Thermal Kinetic Inductance Detectors for X-Ray Imaging Spectroscopy
Gerhard Ulbricht, Benjamin A. Mazin, Paul Szypryt, Alex B. Walter, Clint Bockstiegel, Bruce Bumble
arXiv:1506.07537 · DOI 10.1063/1.4923096 · 2015-06-24 · arXiv: Instrumentation and Methods for Astrophysics
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
For X-ray imaging spectroscopy, high spatial resolution over a large field of view is often as important as high energy resolution, but current X-ray detectors do not provide both in the same device. Thermal Kinetic Inductance Detectors (TKIDs) are being developed as they offer a feasible way to combine the energy resolution of transition edge sensors with pixel counts approaching CCDs and thus promise significant improvements for many X-ray spectroscopy applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors (MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels have recently been demonstrated and much bigger arrays are under development. In this work, we present our first working TKID prototypes which are able to achieve an energy resolution of 75 eV at 5.9 keV, even though their general design still has to be optimized. We further describe TKID fabrication, characterization, multiplexing and working principle and demonstrate the necessity of a data fitting algorithm in order to extract photon energies. With further design optimizations we expect to be able to improve our TKID energy resolution to less than 10 eV at 5.9 keV.
Similar papers
A Position Sensitive X-ray Spectrophotometer using Microwave Kinetic Inductance Detectors
similarity 0.87Benjamin A. Mazin et al. · 2006 · arXiv:cond-mat/0610130
Source status unknown — claims are unverified
Ultraviolet, Optical, and Near-IR Microwave Kinetic Inductance Detector Materials Developments
similarity 0.86P. Szypryt et al. · 2014 · arXiv:1412.0724
Source status unknown — claims are unverified
Thermoelectric radiation detector based on superconductor/ferromagnet systems
similarity 0.85T. T. Heikkilä et al. · 2017 · arXiv:1709.08856
Source status unknown — claims are unverified
Performance of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors as Direct Detectors for Sub-millimeter Astronomy
similarity 0.85R. M. J. Janssen et al. · 2014 · arXiv:1408.3314
Source status unknown — claims are unverified
Crosstalk Reduction for Superconducting Microwave Resonator Arrays
similarity 0.85Omid Noroozian et al. · 2012 · arXiv:1206.5571
Source status unknown — claims are unverified
Power Handling and Responsivity of Submicron Wide Superconducting Coplanar Waveguide Resonators
similarity 0.85R. M. J. Janssen et al. · 2012 · arXiv:1206.0579
Source status unknown — claims are unverified