Performance of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors as Direct Detectors for Sub-millimeter Astronomy
R. M. J. Janssen, J. J. A. Baselmans, A. Endo, L. Ferrari, S. J. C. Yates, A. M. Baryshev, T. M. Klapwijk
arXiv:1408.3314 · DOI 10.1117/12.2055537 · 2014-08-14
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
In the next decades millimeter and sub-mm astronomy requires large format imaging arrays and broad-band spectrometers to complement the high spatial and spectral resolution of the Atacama Large Millimeter/sub-millimeter Array. The desired sensors for these instruments should have a background limited sensitivity and a high optical efficiency and enable arrays thousands of pixels in size. Hybrid microwave kinetic inductance detectors consisting of NbTiN and Al have shown to satisfy these requirements. We present the second generation hybrid NbTiN-Al MKIDs, which are photon noise limited in both phase and amplitude readout for loading levels $P_{850GHz} \geq 10$ fW. Thanks to the increased responsivity, the photon noise level achieved in phase allows us to simultaneously read out approximately 8000 pixels using state-of-the-art electronics. In addition, the choice of superconducting materials and the use of a Si lens in combination with a planar antenna gives these resonators the flexibility to operate within the frequency range $0.09 < ν< 1.1$ THz. Given these specifications, hybrid NbTiN-Al MKIDs will enable astronomically usable kilopixel arrays for sub-mm imaging and moderate resolution spectroscopy.
Source-reported materials — not catalogue approval
| Formula | Reported Tc (K) | Pressure (GPa) | Type |
|---|---|---|---|
| NbTiN Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | 14 | Pressure not reported | unknown |
| Al Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | 1.28 | Pressure not reported | unknown |
Similar papers
Investigation of Quasi-particle Relaxation in Strongly Disordered Superconductor Resonators
similarity 0.89Jie Hu et al. · 2024 · arXiv:2404.10785
Source status unknown — claims are unverified
Power Handling and Responsivity of Submicron Wide Superconducting Coplanar Waveguide Resonators
similarity 0.89R. M. J. Janssen et al. · 2012 · arXiv:1206.0579
Source status unknown — claims are unverified
High optical efficiency and photon noise limited sensitivity of microwave kinetic inductance detectors using phase readout
similarity 0.88R. M. J. Janssen et al. · 2013 · arXiv:1311.2429
Source status unknown — claims are unverified
Equivalence of Optical and Electrical Noise Equivalent Power of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors
similarity 0.88R. M. J. Janssen et al. · 2014 · arXiv:1408.3272
Source status unknown — claims are unverified
Tunable responsivity and bandwidth in microwave kinetic inductance detectors via readout current nonlinearity
similarity 0.88Maclean Rouble et al. · 2026 · arXiv:2607.09178
Source status unknown — claims are unverified
Photon noise from chaotic and coherent millimeter-wave sources measured with horn-coupled, aluminum lumped-element kinetic inductance detectors
similarity 0.87Daniel Flanigan et al. · 2015 · arXiv:1510.06609
Source status unknown — claims are unverified