Photon noise from chaotic and coherent millimeter-wave sources measured with horn-coupled, aluminum lumped-element kinetic inductance detectors
Daniel Flanigan, Heather McCarrick, Glenn Jones, Bradley R. Johnson, Maximilian H. Abitbol, Peter Ade, Derek Araujo, Kristi Bradford, Robin Cantor, George Che, Peter K. Day, Simon Doyle, Carl Bjorn Kjellstrand, Henry G LeDuc, Michele Limon, Vy Luu, Philip Mauskopf, Amber Miller, Tony Mroczkowski, Carole Tucker, Jonas Zmuidzinas
arXiv:1510.06609 · DOI 10.1063/1.4942804 · 2015-10-22 · arXiv: Instrumentation and Methods for Astrophysics
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to produce radiation between 140 and 160 GHz. We feed the multiplier with either amplified broadband noise or a continuous-wave tone from a microwave signal generator. We demonstrate that the detector response over a 40 dB range of source power is well-described by a simple model that considers the number of quasiparticles. The detector noise-equivalent power (NEP) is dominated by photon noise when the absorbed power is greater than approximately 1 pW, which corresponds to $\mathrm{NEP} \approx 2 \times 10^{-17} \, \mathrm{W} \, \mathrm{Hz}^{-1/2}$, referenced to absorbed power. At higher source power levels we observe the relationships between noise and power expected from the photon statistics of the source signal: $\mathrm{NEP} \propto P$ for broadband (chaotic) illumination and $\mathrm{NEP} \propto P^{1/2}$ for continuous-wave (coherent) illumination.
Source-reported materials — not catalogue approval
| Formula | Reported Tc (K) | Pressure (GPa) | Type |
|---|---|---|---|
| Al Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | 1.39 | Pressure not reported | unknown |
Similar papers
Magnetic field dependence of the internal quality factor and noise performance of lumped-element kinetic inductance detectors
similarity 0.87Daniel Flanigan et al. · 2016 · arXiv:1609.06352
Source status unknown — claims are unverified
Photon-noise limited sensitivity in titanium nitride kinetic inductance detectors
similarity 0.87Johannes Hubmayr et al. · 2014 · arXiv:1406.4010
Source status unknown — claims are unverified
High quality factor manganese-doped aluminum lumped-element kinetic inductance detectors sensitive to frequencies below 100 GHz
similarity 0.87G. Jones et al. · 2017 · arXiv:1701.08461
Source status unknown — claims are unverified
Probing flux and charge noise with macroscopic resonant tunneling
similarity 0.86Alexander M. Whiticar et al. · 2022 · arXiv:2210.01714
Source status unknown — claims are unverified
Performance of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors as Direct Detectors for Sub-millimeter Astronomy
similarity 0.86R. M. J. Janssen et al. · 2014 · arXiv:1408.3314
Source status unknown — claims are unverified
Towards the Heisenberg limit in microwave photon detection by a qubit array
similarity 0.86P. Navez et al. · 2020 · arXiv:2009.11271
Source status unknown — claims are unverified