High quality factor manganese-doped aluminum lumped-element kinetic inductance detectors sensitive to frequencies below 100 GHz
G. Jones, B. R. Johnson, M. H. Abitbol, P. A. R. Ade, S. Bryan, H. -M. Cho, P. Day, D. Flanigan, K. D. Irwin, D. Li, P. Mauskopf, H. McCarrick, A. Miller, Y. R. Song, C. Tucker
arXiv:1701.08461 · DOI 10.1063/1.4984105 · 2017-01-30 · Applied Physics Letters
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
Aluminum lumped-element kinetic inductance detectors (LEKIDs) sensitive to millimeter-wave photons have been shown to exhibit high quality factors, making them highly sensitive and multiplexable. The superconducting gap of aluminum limits aluminum LEKIDs to photon frequencies above 100 GHz. Manganese-doped aluminum (Al-Mn) has a tunable critical temperature and could therefore be an attractive material for LEKIDs sensitive to frequencies below 100 GHz if the internal quality factor remains sufficiently high when manganese is added to the film. To investigate, we measured some of the key properties of Al-Mn LEKIDs. A prototype eight-element LEKID array was fabricated using a 40 nm thick film of Al-Mn deposited on a 500 μm thick high-resistivity, float-zone silicon substrate. The manganese content was 900 ppm, the measured $T_c = 694\pm1$ mK, and the resonance frequencies were near 150 MHz. Using measurements of the forward scattering parameter $S_{21}$ at various bath temperatures between 65 and 250 mK, we determined that the Al-Mn LEKIDs we fabricated have internal quality factors greater than $2 \times 10^5$, which is high enough for millimeter-wave astrophysical observations. In the dark conditions under which these devices were measured, the fractional frequency noise spectrum shows a shallow slope that depends on bath temperature and probe tone amplitude, which could be two-level system noise. The anticipated white photon noise should dominate this level of low-frequency noise when the detectors are illuminated with millimeter-waves in future measurements. The LEKIDs responded to light pulses from a 1550 nm light-emitting diode, and we used these light pulses to determine that the quasiparticle lifetime is 60 μs.
Source-reported materials — not catalogue approval
| Formula | Reported Tc (K) | Pressure (GPa) | Type |
|---|---|---|---|
| Al Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | 1.4 | Pressure not reported | unknown |
| Al-Mn Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | 0.694 | Pressure not reported | unknown |
| Al-Mn Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | 0.73 | Pressure not reported | unknown |
Similar papers
Strong Negative Electrothermal Feedback in Thermal Kinetic Inductance Detectors
similarity 0.88Shubh Agrawal et al. · 2021 · arXiv:2107.12493
Source status unknown — claims are unverified
Photon-noise limited sensitivity in titanium nitride kinetic inductance detectors
similarity 0.88Johannes Hubmayr et al. · 2014 · arXiv:1406.4010
Source status unknown — claims are unverified
Photon noise from chaotic and coherent millimeter-wave sources measured with horn-coupled, aluminum lumped-element kinetic inductance detectors
similarity 0.88Daniel Flanigan et al. · 2015 · arXiv:1510.06609
Source status unknown — claims are unverified
FFTS readout for large arrays of Microwave Kinetic Inductance Detectors
similarity 0.88S. J. C. Yates et al. · 2009 · arXiv:0903.2431
Source status unknown — claims are unverified
Microresonators fabricated from high-kinetic-inductance Aluminum films
similarity 0.87Wenyuan Zhang et al. · 2018 · arXiv:1807.00210
Source status unknown — claims are unverified
Microwave characterization of superconducting coplanar resonators made out of granular aluminium
similarity 0.87Kelvin J. Ramos et al. · 2025 · arXiv:2508.03873
Source status unknown — claims are unverified