Tunable responsivity and bandwidth in microwave kinetic inductance detectors via readout current nonlinearity
Maclean Rouble, Peter Day, Matt Dobbs, Joshua Montgomery, Sofiia Savchyn, Graeme Smecher
arXiv:2607.09178 · 2026-08-26
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
Microwave kinetic inductance detectors (MKIDs) are generally read out with microwave readout tones of high enough amplitude to adequately suppress the noise contribution of the first-stage amplifier. At high readout power, the detector's resonant frequency is altered as a result of the dependence of the kinetic inductance on the internally circulating microwave current. With the tone placed below the resonant frequency, the nonlinear frequency shift results in a positive feedback effect that can significantly enhance the responsivity of the detector, to both optical and microwave power. We report a factor of 10 enhancement in optical response by tuning the readout power and frequency to close to the resonator's bifurcation point. A corresponding decrease in the bandwidth of the resonator is observed under these conditions. We show that the strength of the feedback effect can be easily selected by adjusting the excitation, and provide a map of possible operational states to do so. Operation of MKIDs in this mode could be used to improve sensitivity when non-intrinsic noise sources are significant.
Source-reported materials — not catalogue approval
| Formula | Reported Tc (K) | Pressure (GPa) | Type |
|---|---|---|---|
| TiN Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | — | Pressure not reported | unknown |
| NbN Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | — | Pressure not reported | unknown |
| Nb Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | — | Pressure not reported | unknown |
Similar papers
Investigation of Quasi-particle Relaxation in Strongly Disordered Superconductor Resonators
similarity 0.89Jie Hu et al. · 2024 · arXiv:2404.10785
Source status unknown — claims are unverified
A compact and tunable forward coupler based on high-impedance superconducting nanowires
similarity 0.88Marco Colangelo et al. · 2020 · arXiv:2011.11406
Source status unknown — claims are unverified
Increased multiplexing of superconducting microresonator arrays by post-characterization adaptation of the on-chip capacitors
similarity 0.88Shibo Shu et al. · 2018 · arXiv:1808.03779
Source status unknown — claims are unverified
Nonequilibrium pulse dynamics and metastable latching in nonlinear kinetic inductance detectors
similarity 0.88M. Rouble et al. · 2026 · arXiv:2608.23902
Source status unknown — claims are unverified
FFTS readout for large arrays of Microwave Kinetic Inductance Detectors
similarity 0.87S. J. C. Yates et al. · 2009 · arXiv:0903.2431
Source status unknown — claims are unverified
Strongly non-linear superconducting silicon resonators
similarity 0.87P. Bonnet et al. · 2021 · arXiv:2101.11125
Source status unknown — claims are unverified