Abstract
The deployment of large cryogenic detector arrays, comprising hundreds to thousands of individual detectors, is highly beneficial for various cutting-edge applications, requiring large statistics, angular resolution or imaging capabilities. The readout of such arrays, however, presents a major challenge in terms of system complexity, parasitic heat load, and cost, which can be overcome only through multiplexing. Among the various multiplexing approaches, microwave SQUID multiplexing currently represents the state of the art, in particular for magnetic microcalorimeter (MMC) readout. In this work, we demonstrate the successful operation of the latest generation of our microwave SQUID multiplexer-based readout system, based on a SQUID multiplexer tailored for MMC readout and a custom full-scale software-defined radio (SDR) electronics, capable of handling up to 400 channels. The system operates reliably across the entire 4-8 GHz frequency band and achieves sufficiently low flux noise levels in flux-ramp-demodulated readout. Our results confirm that our system is fully functional and provides a scalable path towards future large-scale, high-resolution MMC experiments.
Similar papers
Tunable coupling of transmission-line microwave resonators mediated by an rf SQUID
similarity 0.90F. Wulschner et al. · 2015 · arXiv:1508.06758
Source status unknown — claims are unverified
Simultaneous MMC readout using a tailored μMUX based readout system
similarity 0.90Daniel Richter et al. · 2022 · arXiv:2211.07127
Source status unknown — claims are unverified
Development of a microwave SQUID multiplexer for magnetic microbolometers
similarity 0.89N. Müller et al. · 2025 · arXiv:2509.23507
Source status unknown — claims are unverified
Analytical model of the readout power and SQUID hysteresis parameter dependence of the resonator characteristics of microwave SQUID multiplexers
similarity 0.88Mathias Wegner et al. · 2021 · arXiv:2112.08278
Source status unknown — claims are unverified
Flux ramp modulation based MHz frequency-division dc-SQUID multiplexer
similarity 0.88Daniel Richter et al. · 2021 · arXiv:2101.06424
Source status unknown — claims are unverified
A dispersive nanoSQUID magnetometer for ultra-low noise, high bandwidth flux detection
similarity 0.88E. M. Levenson-Falk et al. · 2013 · arXiv:1301.3184
Source status unknown — claims are unverified