Experimental Results from Early Non-Planar NI-HTS Magnet Prototypes for the Columbia Stellarator eXperiment (CSX)
D. Schmeling, M. Russo, B. T. Gebreamlak, T. J. Kiker, A. R. Skrypek, A. R. Hightower, J. Xue, S. Chen, S. Sohaib, C. Martinez, K. F. Richardson, L. Filor, S. Komatsu, L. Liu, C. Paz-Soldan
arXiv:2510.07042 · DOI 10.1109/TPS.2026.3681798 · 2025-10-08 · IEEE Transactions on Plasma Science
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
The Columbia Stellarator eXperiment (CSX) is an upgrade of the Columbia Non-neutral Torus (CNT) that aims to demonstrate a university-scale, quasi-axisymmetric stellarator using high-temperature superconducting (HTS) technology at an on-axis magnetic field target of 0.5 T. Due to the strain sensitivity of ReBCO (Rare-earth Barium Copper Oxides), adapting it to non-planar stellarator geometries requires new winding, structural, and cooling strategies. We report on the results of a staged prototype program (P1, P2, P3) employing 3D-printed, sectional aluminum coil frames with winding channels, gimballed constant-tension winding mechanics, and solder potting for radial current redistribution and passive quench mitigation. The first prototype, P1 (planar elliptical, double-pancake) tested additive manufacture, sectional joining and baseline winding, achieving predicted fields at 77 K. P2 (non-planar, higher strain) was wound to 42 turns, energized at 30-40 K to produce expected magnetic fields, and studied thermal gradients and resistance at up to 4.5 kAt. Design evolution in P3 introduces concave geometry with dual double-pancakes, 200 turns, and approaches the 70 kAt target at 20 K. In parallel, sub-microhm lap joints have been developed. Together, these results de-risk manufacturing, cooling interfaces, quench management, and diagnostics, paving the way for full-size non-planar HTS stellarator coils for CSX.
Similar papers
Apparatus for high resolution microwave spectroscopy in strong magnetic fields
similarity 0.82W. A. Huttema et al. · 2005 · arXiv:cond-mat/0510401
Source status unknown — claims are unverified
Scanning Tunneling Microscopy in high vectorial magnetic fields
similarity 0.82Jaime Rumeu Ozores et al. · 2026 · arXiv:2603.01226
Source status unknown — claims are unverified
Exchange parameters of copper-based quasi-two-dimensional Heisenberg magnets measured using high magnetic fields and muon-spin rotation
similarity 0.82P. A. Goddard et al. · 2008 · arXiv:0803.4169
Source status unknown — claims are unverified
He sample probe for combined microwave and dc transport measurements
similarity 0.82Oleksandr V. Dobrovolskiy et al. · 2015 · arXiv:1504.01936
Source status unknown — claims are unverified
Design and performance of an ultra-high vacuum scanning tunneling microscope operating at dilution refrigerator temperatures and high magnetic fields
similarity 0.81Shashank Misra et al. · 2013 · arXiv:1310.1046
Source status unknown — claims are unverified
A Non-planar ReBCO Test Coil with 3D-printed Aluminum Support Structure for the EPOS Stellarator
similarity 0.81Paul Huslage et al. · 2025 · arXiv:2505.08488
Source status unknown — claims are unverified