Design study of compact medical accelerator using superconducting rf quadrupole for boron neutron capture therapy
Ryo Katayama, Eiji Kako, Seiya Yamaguchi, Shinichiro Michizono, Kensei Umemori, Yasuhiro Kondo
DOI 10.1103/PhysRevAccelBeams.25.021601 · Physical Review Accelerators and Beams
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
We investigated the feasibility on the application of a superconducting radio frequency (SRF) niobium cavity to an accelerator-based neutron source for boron neutron capture therapy (BNCT). Neutron source is the key component of BNCT and adopting rf-linac based neutron source realizes a medical care system sufficient to be compact, which can be installed in a hospital and to generate intensive neutron yields that the BNCT requires. However, it is still desirable to improve the efficiency of input power on neutron yields and the achievable accelerate field gradient. SRF accelerator technology potentially allows us to enhance the performance because of its prominent lower ohmic loss and higher sustainable accelerating fields. This paper presents a first feasibility study on the application of a SRF niobium cavity to an accelerator-based neutron source for BNCT, assuming that a superconducting radio frequency quadrupole (SC-RFQ) composed of pure bulk niobium at 4.2 K accelerates the proton/deuteron beams to a beryllium or lithium target for the neutron production of BNCT via Li7(p,n)Be7, Be9(p,n)B9, or Be9(d,n)B10. The following beam parameters were used: beam energy of 2.5 MeV (for Li target)/5 MeV (for Be target), ion source current (50 keV, CW 30 mA), normalized beam emittance of 0.02 cm mrad, and resonance frequency of 325 MHz (for proton)/162.5 MHz (for deuteron). Based on these conditions, we evaluated the feasibility on the following three criteria: comparison of the cooling capacity of the refrigerator to the amount of heat, power consumption of AC, and size of the BNCT system. First, we evaluated the amount of heat generated in a cryomodule by adding the ohmic loss of SC-RFQ Qrf, beam losses in SC-RFQ Qb, heat penetration into the cryomodule Qext, and beam losses of molecular ion beams and poor quality beams emitted from the ion-source at/near the RFQ entrance Qemit. In this study, we typically regarded Qext as 20 W at 4.2 K and considered a new low-energy beam transport system that can suppress Qemit to 0. In addition, Qrf and Qb were numerically evaluated by beam simulation and electromagnetic calculation. The obtained results revealed that the sum of the heat amounts could be sufficiently suppressed below the typical cooling capacity of a commercially available helium refrigerator. Second, we compared the ac power consumption of BNCT between a conventional and SC-BNCT systems, which indicated that the BNCT system adopting the SRF cavity effectively reduced the ac power consumption of SC-BNCT by almost 1/4 times. Third, the length of the SC-RFQ could be shortened by adjusting the peak surface E-field, as compared to conventional existing RFQs such as J-PARC, SNS, and IFMIF. Eventually, this study demonstrated that the application of the SRF cavity for the rf-linac-based neutron source of BNCT is feasible, and thus provides a foundation for the future development of design for next-generation BNCT systems.
Source-reported materials — not catalogue approval
| Formula | Reported Tc (K) | Pressure (GPa) | Type |
|---|---|---|---|
| Nb Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | 9.2 | Pressure not reported | unknown |
Similar papers
Superconducting linac at Inter-University Accelerator Centre: Operational challenges and solutions
similarity 0.95S. Ghosh et al.
Source status unknown — claims are unverified
Understanding Quality Factor Degradation in Superconducting Niobium Cavities at Low Microwave Field Amplitudes
similarity 0.94A. Romanenko & D. I. Schuster
Source status unknown — claims are unverified
Search for Superscreening Effects in a Superconductor
similarity 0.93P. Ujić et al.
Source status unknown — claims are unverified
Optimizing the configuration of a superconducting photonic band gap accelerator cavity to increase the maximum achievable gradients
similarity 0.93Evgenya I. Simakov et al.
Source status unknown — claims are unverified
High-Q operation of superconducting rf cavities: Potential impact of thermocurrents on the rf surface resistance
similarity 0.93J.-M. Vogt et al.
Source status unknown — claims are unverified
Superconductor-semiconductor interaction effects in mesoscopic hybrid structures
similarity 0.93F. Rahman et al.
Source status unknown — claims are unverified