← Back to search

Superconducting Solenoid System with Adjustable Shielding Factor for Precision Measurements of the Properties of the Antiproton

Jack A. Devlin, Elise Wursten, James A. Harrington, Takashi Higuchi, Pascal E. Blessing, Matthias J. Borchert, Stefan Erlewein, Jannek J. Hansen, Jonathan Morgner, Matthew A. Bohman, Andreas H. Mooser, Christian Smorra, Markus Wiesinger, Klaus Blaum, Yasuyuki Matsuda, Christian Ospelkaus, Wolfgang Quint, Jochen Walz, Yasunori Yamazaki, Stefan Ulmer

DOI 10.1103/PhysRevApplied.12.044012 · Physical Review Applied

T1

Active bibliographic source — not scientific approval

Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.

Abstract

A superconducting self-shielding three-solenoid system with an adjustable shielding factor is developed, implemented, and characterized using a single antiproton in a Penning trap. With the tuned system, we suppress external magnetic field disturbances by up to a factor of 225 ± 15, allowing antiproton-to-proton charge-to-mass ratio comparisons with fourfold reduced frequency fluctuations and antiproton magnetic moment determinations with tenfold reduced uncertainty.

Source-reported materials — not catalogue approval

FormulaReported Tc (K)Pressure (GPa)Type
NbTi

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

9.5Pressure not reportedonset

Similar papers