← Back to search

Comparative measurements of ITER Nb3Sn strands between two laboratories

J. Lu, S. Hill, D. McGuire, K. Dellinger, A. Nijhuis, W. A. J. Wessel, H. J. G. Krooshoop, K. Chan, N. N. Martovestky

arXiv:1701.00446 · DOI 10.1109/TASC.2017.2685502 · 2016-12-17 · IEEE Transactions on Applied Superconductivity

T1theoretical4 citations

Active bibliographic source — not scientific approval

Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.

Abstract

ITER Nb3Sn strand quality verification tests require large quantities of precise measurements. Therefore regular cross-checking between testing laboratories is critically important. In this paper, we present results from a cross-checking test of 140 samples between the National High Magnetic Field Laboratory, USA and the University of Twente, the Netherlands. The tests comprise measurements at 4.2 K on critical current, RRR and hysteresis loss, while at room temperature the chromium layer thickness, Cu/nonCu ratio, filament twist pitch, and diameter were determined. Our results show very good agreement between the two labs. The reasons for small random discrepancies are discussed.

Source-reported materials — not catalogue approval

FormulaReported Tc (K)Pressure (GPa)Type
Nb3Sn

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

—Pressure not reportedunknown
Nb3Sn

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

—Pressure not reportedunknown