Superconducting Cables Characterization with an electrical method
L. Morici, E. Tamburo De Bella, G. Messina
arXiv:1809.07145 · 2018-09-19 · arXiv: Superconductivity
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
AC losses in High Temperature Superconductor tapes (HTS) are an important design parameter for large scale power applications. The electrical method is often used for losses measurements on SC tapes and, when the results are to be compared to computed estimations, simple theoretical models like the Norris Brandt are typically used. Electromagnetic dynamic effects are not usually taken into account by the simpler models, but their presence may corrupt the measured data. In this paper, a preliminary study on a conventional copper bar sample has been done to evaluate the effect of the skin currents on the specimen losses measures obtained from the electrical method. The measurement procedure has afterward been applied to a SC YBCO tape (Superpower SCS4050AP), obtaining circuit configuration dependent results. Because the SC losses must obviously be measurement circuit independent, a systematic error due to the skin currents must be playing a role. The skin current induced error is always there and, in order to apply the electrical method for losses estimation, the only possibility is its minimization. The best choice for the measurement circuit to be adopted, in order to minimize the skin current undesired contribution, will finally be proposed.
Similar papers
Determination of I-V Curves of HTS Tapes From The Frequency Dependent AC Transport Loss
similarity 0.89Eduard Demenčík et al. · 2015 · arXiv:1511.08347
Source status unknown — claims are unverified
Influence of the voltage taps position on the self-field DC and AC transport characterization of HTS superconducting tapes
similarity 0.89M. Vojenciak et al. · 2013 · arXiv:1308.3045
Source status unknown — claims are unverified
New Experimental Method for Investigating AC-losses in Concentric HTS Power Cables
similarity 0.86Steffen Elschner et al. · 2014 · arXiv:1411.0933
Source status unknown — claims are unverified
Practical Forecasting of AC Losses in Multi-layer 2G-HTS Cold Dielectric Conductors
similarity 0.86M. Clegg & H. S. Ruiz · 2022 · arXiv:2210.11345
Source status unknown — claims are unverified
Numerical evaluation of AC losses in an HTS insert coil for high field magnet during its energization
similarity 0.85K. Kajikawa et al. · 2014 · arXiv:1405.7765
Source status unknown — claims are unverified
Interfilament Resistance at 77 K in Striated HTS Coated Conductors
similarity 0.85R. Gyuráki et al. · 2016 · arXiv:1605.00401
Source status unknown — claims are unverified