The role of kinetic inductance on the performance of YBCO SQUID magnetometers
Ruffieux, S., Kalaboukhov, A., Xie, M., Chukharkin, M., Pfeiffer, C., Sepehri, S., Schneiderman, J. F., Winkler, D.
arXiv:1910.03991 · DOI 10.1088/1361-6668/ab6014 · 2020-01-29
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
Inductance is a key parameter when optimizing the performance of superconducting quantum interference device (SQUID) magnetometers made from the high temperature superconductor YBa$_2$Cu$_3$O$_{7-x}$ (YBCO) because lower SQUID inductance $L$ leads to lower flux noise, but also weaker coupling to the pickup loop. In order to optimize the SQUID design, we combine inductance simulations and measurements to extract the different inductance contributions, and measure the dependence of the transfer function $V_Φ$ and flux noise $S_Φ^{1/2}$ on $L$. A comparison between two samples shows that the kinetic inductance contribution varies strongly with film quality, hence making inductance measurements a crucial part of the SQUID characterization. Thanks to the improved estimation of the kinetic inductance contribution, previously found discrepancies between theoretical estimates and measured values of $V_Φ$ and $S_Φ^{1/2}$ could to a large extent be avoided. We then use the measurements and improved theoretical estimations to optimize the SQUID geometry and reach a noise level of $S_B^{1/2}$ = 44 fT/$\sqrt{\textrm{Hz}}$ for the best SQUID magnetometer with a 8.6 mm $\times$ 9.2 mm directly coupled pickup loop. Lastly, we demonstrate a method for reliable one-time sensor calibration that is constant in a temperature range of several kelvin despite the presence of temperature dependent coupling contributions, such as the kinetic inductance. The found variability of the kinetic inductance contribution has implications not only for the design of YBCO SQUID magnetometers, but for all narrow linewidth SQUID-based devices operated close to their critical temperature.
Source-reported materials — not catalogue approval
| Formula | Reported Tc (K) | Pressure (GPa) | Type |
|---|---|---|---|
| YBa2Cu3O7-x Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | 87.7 | Pressure not reported | unknown |
| YBa2Cu3O7-x Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | 89 | Pressure not reported | unknown |
Similar papers
A Tunable Monolithic SQUID in Twisted Bilayer Graphene
similarity 0.91Elías Portolés et al. · 2022 · arXiv:2201.13276
Source status unknown — claims are unverified
Inductance measurement of YBCO strip-lines made by ion irradiation
similarity 0.89T. Wolf et al. · 2010 · arXiv:1008.4042
Source status unknown — claims are unverified
Magnetic field dependence of the internal quality factor and noise performance of lumped-element kinetic inductance detectors
similarity 0.89Daniel Flanigan et al. · 2016 · arXiv:1609.06352
Source status unknown — claims are unverified
MgB2 tunnel junctions and 19 K low-noise dc superconducting quantum interference devices
similarity 0.89Y. Zhang et al. · 2001 · arXiv:cond-mat/0107478
Source status unknown — claims are unverified
Simulation framework for microwave SQUID multiplexer optimization
similarity 0.89Constantin Schuster et al. · 2022 · arXiv:2208.02013
Source status unknown — claims are unverified
Superconducting receiver arrays for magnetic resonance imaging
similarity 0.89Koos C. J. Zevenhoven et al. · 2018 · arXiv:1805.08867
Source status unknown — claims are unverified