Precise magnetization measurements down to 500 mK using a miniature 3He cryostat and a closed-cycle 3He gas handling system installed in a SQUID magnetometer without continuous-cooling functionality
Kazutoshi Shimamura, Hiroki Wajima, Hayato Makino, Satoshi Abe, Yoshinori Haga, Yoshiaki Sato, Tatsuya Kawae, Yasuo Yoshida
arXiv:2202.09067 · DOI 10.35848/1347-4065/ac5bb0 · 2022-02-18
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
We have conducted precise magnetization measurements down to 0.5 K with a miniature 3He cryostat and a closed-cycle 3He gas handling system for a commercial superconducting quantum interference device magnetometer [Magnetic Property Measurement System (Quantum Design)]. The gas handling system contains two sorption pumps filled with granular charcoals. We pressurize 3He gas up to ambient pressure for the liquification at 3 K and then pump the vaper for cooling. The lowest sample temperature is ~ 0.5 K and it can persist for 34 hours. We demonstrate the performance of the system by observing the Meissner effect of aluminum below the superconducting transition temperature ~ 1 K. We also measured the magnetization curve of the heavy fermion superconductor CeCoIn5 resulting in successful observation of the lower critical field at 0.5 K.
Source-reported materials — not catalogue approval
| Formula | Reported Tc (K) | Pressure (GPa) | Type |
|---|---|---|---|
| Al Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | 1 | Pressure not reported | unknown |
| CeCoIn5 Archive — visibility unverified Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula. | — | Pressure not reported | — |
Similar papers
Tiny adiabatic-demagnetization refrigerator for a commercial superconducting quantum interference device magnetometer
similarity 0.87Taku J Sato et al. · 2016 · arXiv:1612.01376
Source status unknown — claims are unverified
Micro-coil detection of Nuclear Magnetic Resonance for nanofluidic samples
similarity 0.84Aya Shibahara et al. · 2013 · arXiv:1311.2007
Source status unknown — claims are unverified
Ultralow Mechanical Damping with Meissner-Levitated Ferromagnetic Microparticles
similarity 0.84A. Vinante et al.
Source status unknown — claims are unverified
Hybrid superconducting quantum magnetometer
similarity 0.84F. Giazotto & F. Taddei
Source status unknown — claims are unverified
Design of an experimental platform for hybridization of atomic and superconducting quantum systems
similarity 0.83Alessandro Landra et al.
Source status unknown — claims are unverified
Scanned SQUID Microscope with High-speed Electrical Connectivity
similarity 0.83Ian W. Haygood et al. · 2025 · arXiv:2509.07137
Source status unknown — claims are unverified