SQUID current sensors with an integrated thermally actuated input current limiter
Rainer Körber, Patryk Krzysteczko, Monique Klemm, Tianhao Liu, Jan-Hendrik Storm, Jörn Beyer
arXiv:2302.13821 · DOI 10.1088/1361-6668/acd607 · 2023-02-27 · Superconductor Science and Technology
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
The development of SQUID current sensors with a thermally actuated input current limiter (TCL) integrated into the input circuit of the sensor is presented. The TCL is based on an unshunted Josephson Junction (JJ) series array, around which meanders a galvanically isolated, but tightly, thermally coupled, resistive heater element. By applying a current to the heater, the JJ critical currents can be reduced or completely suppressed, while the other on-chip SQUID circuit elements remain unaffected. The functional parameters of the TCL are determined by direct transport measurements and by static and dynamic flux coupling tests via the input circuit. In liquid Helium, a heater power, which reliably suppresses the critical current of the JJ array to zero, of $\sim$1.5 mW was needed, with the TCL normal state resistance being at 500 $Ω$. In this configuration, typical TCL switching times below 10 $μ$s were observed in the direct transport measurements. The TCL can be used to temporarily or even permanently disable malfunctioning channels in multichannel SQUID magnetometer systems, when feedback into their otherwise superconducting input circuits is not possible. In doing so, significant signal distortions in neighbouring channels from screening currents in these input circuits are avoided. Furthermore, by completely suppressing and restoring the TCL critical current, dc offset currents in the superconducting input circuits can be prevented. This is relevant, for instance, in SQUID-based spin precession experiments on hyperpolarized noble gases, in which even dc currents of a few $μ$A in the input circuit can lead to significant magnetic field distortions in the adjacent sample region contributing to the transverse spin-spin relaxation rate $1/T_{2}$
Similar papers
An ultra-sensitive and wideband magnetometer based on a superconducting quantum interference device
similarity 0.87Jan-Hendrik Storm et al. · 2017 · arXiv:1702.05428
Source status unknown — claims are unverified
Noise scaling in SQUID arrays
similarity 0.86Oscar A. Nieves & Karl-H Müller · 2024 · arXiv:2409.19837
Source status unknown — claims are unverified
Ultra-sensitive SQUID instrumentation for MEG and NCI by ULF MRI
similarity 0.86Rainer Körber · 2019 · arXiv:1903.09401
Source status unknown — claims are unverified
MgB2 tunnel junctions and 19 K low-noise dc superconducting quantum interference devices
similarity 0.86Y. Zhang et al. · 2001 · arXiv:cond-mat/0107478
Source status unknown — claims are unverified
A Magnetic Persistent Current Switch at milliKelvin Temperatures
similarity 0.86Bob van Waarde et al. · 2016 · arXiv:1601.02439
Source status unknown — claims are unverified
Superconducting quantum interference devices with submicron Nb/HfTi/Nb junctions for investigation of small magnetic particles
similarity 0.86J. Nagel et al. · 2011 · arXiv:1106.1985
Source status unknown — claims are unverified