← Back to search

First non-zero measurement of a nuclear electric dipole moment

Gary Prézeau

arXiv:2510.21768 · 2025-10-16

T2theoretical

Active bibliographic source — not scientific approval

Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.

Abstract

This paper reports the first non-zero measurement of a nuclear electric dipole moment using a novel method based on the rate of change of a supercurrent first proposed in 2016~\cite{https://doi.org/10.48550/arxiv.1604.02152} and fleshed out in this current paper. The theory, experimental concept and implementation are described in detail. The non-zero nuclear electric dipole moment measured with over 1000 hours of data was that of $^{181}$Ta producing a best value $|d_\text{e}^\text{Ta}|=(3.39\pm0.31_\text{stat})\cdot10^{-32}e\cdot\text{cm}$ and $|d_\text{e}^\text{Ta}|=(3.39\pm3.18)\cdot10^{-32}e\cdot\text{cm}>0$ at 99.985\%CL. There is an uncertainty on the value of overall multiplicative parameters such as the self-inductance of the superconducting circuit ($\pm4\%$), the mutual inductance between the SQUID pickup coil and the sample wire ($\pm15\%$), and the magnitude of the solenoid current ($\pm5\%$). An upper-limit was estimated for the control element, $^{207}$Pb, $|d_\text{e}^\text{Pb}|\lesssim1.2\cdot10^{-31}e\cdot\text{cm}$ at 95\%CL.

Source-reported materials — not catalogue approval

FormulaReported Tc (K)Pressure (GPa)Type
H3S

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

750 GPaunknown
Li

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

0.0004Pressure not reportedunknown
C2Li

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

1.9Pressure not reportedunknown
Be

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

0.026Pressure not reportedunknown
YB6

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

8.4Pressure not reportedunknown
SiC:B

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

1.5Pressure not reportedunknown
SiC:Al

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

1.4Pressure not reportedunknown
TiN

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

5.6Pressure not reportedunknown
ZrN

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

10Pressure not reportedunknown
NbN

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

16Pressure not reportedunknown
TiOx

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

1Pressure not reportedunknown
NbOx

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

1Pressure not reportedunknown
C3K

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

3Pressure not reportedunknown
C6K

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

1.5Pressure not reportedunknown
Pb

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

7.19Pressure not reportedunknown
Bi

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

0.00053Pressure not reportedunknown
Bi1-xPbx

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

9Pressure not reportedunknown

Similar papers