Characterization of Silicon-Membrane TES Microcalorimeters for Large-Format X-ray Spectrometers with Integrated Microwave SQUID Readout
Avirup Roy, Robinjeet Singh, Joel C. Weber, W. B. Doriese, Johnathon Gard, Mark W. Keller, John A. B. Mates, Kelsey M. Morgan, Nathan J. Ortiz, Daniel S. Swetz, Daniel R. Schmidt, Joel N. Ullom, Evan P. Jahrman, Thomas C. Allison, Sasawat Jamnuch, John Vinson, Charles J. Titus, Cherno Jaye, Daniel A. Fischer, Galen C. O'Neil
arXiv:2601.09629 · DOI 10.1109/TASC.2026.3655165 · 2026-01-14 · IEEE Transactions on Applied Superconductivity
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
We present the electro-thermal characterization of transition-edge sensor (TES) detectors suspended on Si membranes fabricated using a silicon-on-insulator (SOI) wafer. The use of an all-silicon fabrication platform, in contrast to the more commonly used silicon nitride membranes, is compatible with monolithic fabrication of integrated TES and SQUID circuits. The all-silicon architecture additionally allows efficient use of focal plane area; the readout circuitry may be positioned out of the focal plane by bending a thinned portion of the chip. Compatibility with integrated fabrication and efficient use of focal plane area provide a path to an efficient soft X-ray spectrometer. This work is motivated by our goal to develop a 10,000-pixel TES spectrometer to overcome critical measurement limitations in catalysis research. The characterization of fragile, carbon-based intermediates via techniques like Resonant Inelastic X-ray Scattering (RIXS) is often precluded by the slow, high-flux nature of existing technologies. The new instrument will allow for fast RIXS measurements to be made without causing sample damage. We verify the detector models and measure the energy resolution using a pulsed optical laser, demonstrating the viability of this approach for the final instrument to be deployed at the National Synchrotron Light Source II (NSLS-II).
Similar papers
A high-speed, high-resolution Transition Edge Sensor spectrometer for soft X-rays at the Advanced Photon Source
similarity 0.86Orlando Quaranta et al. · 2025 · arXiv:2501.01883
Source status unknown — claims are unverified
Hard X-ray Fluorescence measurements with TESs at the Advanced Photon Source
similarity 0.86Tejas Guruswamy et al. · 2019 · arXiv:1909.05919
Source status unknown — claims are unverified
Phonon-trapping enhanced energy resolution in superconducting single photon detectors
similarity 0.86Pieter J. de Visser et al. · 2021 · arXiv:2103.06723
Source status unknown — claims are unverified
Lithographic integration of TES microcalorimeters with SQUID multiplexer circuits for large format spectrometers
similarity 0.86Robinjeet Singh et al. · 2025 · arXiv:2510.07690
Source status unknown — claims are unverified
X-ray photon detection using superconducting resonators in thermal quasi-equilibrium
similarity 0.86Orlando Quaranta et al. · 2013 · arXiv:1304.3387
Source status unknown — claims are unverified
Demonstration of Weak-Link Physics in the Dynamical Response of Transition-Edge Sensors
similarity 0.86Marios Kounalakis et al. · 2022 · arXiv:2212.06443
Source status unknown — claims are unverified