Control of turn-to-turn contact resistivity in resistively insulated REBCO coils
Jun Lu, Kwangmin Kim, Iain Dixon, Justin Deterding, Emsley Marks, Brent Jarvis, Denis Markiewicz, Hongyu Bai, Mark Bird
arXiv:2604.15587 · 2026-04-16
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
Resistively insulated (RI) REBCO magnets feature short ramp times and low ramp losses while maintaining the advantages of no-insulation coils with high engineering current density and tolerance for defects in the REBCO conductor. Control of the turn-to-turn contact resistivity Rc is key to RI technology. Rc must be sufficiently high to prevent a large transient current, which could result in high mechanical stress during magnet quenches. Meanwhile it must be lower than the quench propagation limit to avoid conductor burn-out during a quench. Therefore, it is critical to control Rc within a suitable range of values which is usually coil specific. Previously, we discovered that Rc between two REBCO tapes with a stainless steel interlayer decreases dramatically with contact pressure cycling by up to three orders of magnitude. This drastic change made it impossible to design a suitable Rc value for a stainless steel co-wound RI magnet. In this work, we first present methods for mitigating Rc pressure cycling sensitivity. We found that by adding conductive fillers, such as conductive paste or epoxy, the Rc load cycling sensitivity is largely mitigated. For dry-wound coils, Rc load cycling sensitivity is mitigated by coating REBCO tape with a layer of 2- 3 um of PbSn solder. In addition, Rc can be controlled by oxidizing the stainless steel co-wind tape by heating stainless steel tapes at different temperatures in air. Using above methods, short sample tests showed that Rc was controlled to prescribed values of 1000 and 5000 uOhm-cm2 and was not sensitive to contact pressure cycling up to 30,000 cycles at 4.2 K. The new Rc control method was applied to a 6 double-pancake test coil which was tested at 4.2 K. The Rc in this test coil was comparable with the short sample results. This demonstrated the ability of this new method to control Rc in large coils.
Similar papers
Contact resistivity due to oxide layers between two REBCO tapes
similarity 0.92Jun Lu et al. · 2019 · arXiv:1912.01515
Source status unknown — claims are unverified
Effects of Wax Impregnation on Contact Resistivity Between REBCO Tapes
similarity 0.89Jeremy W. Levitan et al. · 2023 · arXiv:2302.06756
Source status unknown — claims are unverified
Transverse Thermal Conductivity of REBCO Coated Conductors
similarity 0.86Marco Bonura & Carmine Senatore · 2014 · arXiv:1412.1335
Source status unknown — claims are unverified
Observation of REBCO delamination in the resistive insulation nested coils
similarity 0.85Jun Lu et al. · 2025 · arXiv:2512.16647
Source status unknown — claims are unverified
REBCO delamination by transverse electromagnetic stress due to screening current in magnetic field
similarity 0.85Jun Lu et al. · 2025 · arXiv:2507.21301
Source status unknown — claims are unverified
Critical Current, Lengthwise Fluctuations, and Flux Jumps in REBCO CC: A Torque Magnetometry Study up to 45 T
similarity 0.85J. Jaroszynski et al. · 2026 · arXiv:2502.02706
Source status unknown — claims are unverified