← Back to search

High performance temperature controller: application to the excess noise measurements of YBCO thermometers in the transition region

B. Guillet, L. Mechin, D. Robbes

arXiv:cond-mat/0305469 · 2003-05-20 · arXiv: Superconductivity

T1theoretical2 citations

Active bibliographic source — not scientific approval

Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.

Abstract

Dedicated read-out electronics was developed for low impedance resistive thermometers. Using this high performance temperature controller, the temperature dependence of the excess noise of a YBa2Cu307-d (YBCO) sample in the superconducting transition was monitored as a function of the current bias. The noise could reach 3.10-8 K Hz-1/2 at 1 Hz, 5 mA bias and 90 K.

Source-reported materials — not catalogue approval

FormulaReported Tc (K)Pressure (GPa)Type
YBa2Cu3O7-δ

Archive — visibility unverified

Source-occurrence policy only; no material identity or catalogue acceptance is inferred from the formula.

90Pressure not reportedunknown

Similar papers