Abstract
Microwave Kinetic Inductance Detectors, or MKIDs, have proven to be a powerful cryogenic detector technology due to their sensitivity and the ease with which they can be multiplexed into large arrays. A MKID is an energy sensor based on a photon-variable superconducting inductance in a lithographed microresonator, and is capable of functioning as a photon detector across the electromagnetic spectrum as well as a particle detector. Here we describe the first successful effort to create a photon-counting, energy-resolving ultraviolet, optical, and near infrared MKID focal plane array. These new Optical Lumped Element (OLE) MKID arrays have significant advantages over semiconductor detectors like charge coupled devices (CCDs). They can count individual photons with essentially no false counts and determine the energy and arrival time of every photon with good quantum efficiency. Their physical pixel size and maximum count rate is well matched with large telescopes. These capabilities enable powerful new astrophysical instruments usable from the ground and space. MKIDs could eventually supplant semiconductor detectors for most astronomical instrumentation, and will be useful for other disciplines such as quantum optics and biological imaging.
Similar papers
Multiplexable frequency retuning of MKID arrays using their non-linear kinetic inductance
similarity 0.89Mario De Lucia et al. · 2022 · arXiv:2204.05715
Source status unknown — claims are unverified
Superconducting micro-resonator arrays with ideal frequency spacing and extremely low frequency collision rate
similarity 0.89X. Liu et al. · 2017 · arXiv:1711.07914
Source status unknown — claims are unverified
A Position Sensitive X-ray Spectrophotometer using Microwave Kinetic Inductance Detectors
similarity 0.88Benjamin A. Mazin et al. · 2006 · arXiv:cond-mat/0610130
Source status unknown — claims are unverified
Superconducting Materials for Microwave Kinetic Inductance Detectors
similarity 0.88Benjamin A. Mazin · 2020 · arXiv:2004.14576
Source status unknown — claims are unverified
ARCONS: A highly multiplexed superconducting optical to near-IR camera
similarity 0.88Benjamin A. Mazin et al. · 2010 · arXiv:1007.0752
Source status unknown — claims are unverified
Performance of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors as Direct Detectors for Sub-millimeter Astronomy
similarity 0.87R. M. J. Janssen et al. · 2014 · arXiv:1408.3314
Source status unknown — claims are unverified