A near-field scanning SQUID microwave microscope
Vladimir V Talanov, Nesco M Lettsome,, Valery Borzenets, Nicolas Gagliolo, Alfred B Cawthorne, Antonio Orozco
arXiv:1310.0078 · DOI 10.1088/0953-2048/27/4/044032 · 2013-09-30 · Superconductor Science and Technology
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
We developed a scanning DC SQUID microscope with novel readout electronics capable of wideband sensing RF magnetic fields from 50 to 200 MHz and simultaneously providing closed-loop response at kHz frequencies. To overcome the 20 MHz bandwidth limitation of traditional closed-loop SQUIDs, a flux-modulated closed loop simultaneously locks the SQUID quasi-static flux and flux-biases the SQUID for amplification of the RF flux up to $Φ_0/4$ in amplitude. Demodulating the SQUID voltage with a double lock-in technique yields a signal representative of both the amplitude and phase of the RF flux. This provides 80 dB of a linear dynamic range with the flux noise density of 4 $μΦ_0/\sqrt{Hz}$ at 200 MHz for $YBa_2Cu_3O_7$ bi-crystal SQUID at 77 K. We describe the electronics performance and present images for RF magnetic field of the travelling wave in a coplanar waveguide, the standing wave in an open-circuited microstrip, and a surface mounted device antenna.
Similar papers
Scanned SQUID Microscope with High-speed Electrical Connectivity
similarity 0.92Ian W. Haygood et al. · 2025 · arXiv:2509.07137
Source status unknown — claims are unverified
Dispersive magnetometry with a quantum limited SQUID parametric amplifier
similarity 0.90M. Hatridge et al.
Source status unknown — claims are unverified
A micro-SQUID with dispersive readout for magnetic scanning microscopy
similarity 0.90Farshad Foroughi et al. · 2018 · arXiv:1803.07636
Source status unknown — claims are unverified
Dispersive magnetometry with a quantum limited SQUID parametric amplifier
similarity 0.89M. Hatridge et al. · 2010 · arXiv:1003.2466
Source status unknown — claims are unverified
A dispersive nanoSQUID magnetometer for ultra-low noise, high bandwidth flux detection
similarity 0.88E. M. Levenson-Falk et al. · 2013 · arXiv:1301.3184
Source status unknown — claims are unverified
Multi-terminal multi-junction dc SQUID for nanoscale magnetometry
similarity 0.88Alexander Y. Meltzer et al. · 2016 · arXiv:1606.05682
Source status unknown — claims are unverified