Development of the superconducting detectors and read-out for the X-IFU instrument on board of the X-ray observatory Athena
Luciano Gottardi, Hiroki Akamatsu, Marcel P. Bruijn, Roland den Hartog, Jan-Willem den Herder, Brian Jackson, Mikko Kiviranta, Jan van der Kuur, Henk van Weers
arXiv:1604.00670 · DOI 10.1016/j.nima.2015.09.072 · 2016-04-03 · Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
The Advanced Telescope for High-Energy Astrophysics (Athena) has been selected by ESA as its second large-class mission. The future European X-ray observatory will study the hot and energetic Universe with its launch foreseen in 2028. Microcalorimeters based on superconducting Transition-edge sensor (TES) are the chosen technology for the detectors array of the X-ray Integral Field Unit (X-IFU) on board of Athena. The X-IFU is a 2-D imaging integral-field spectrometer operating in the soft X-ray band (0.3 -12 keV). The detector consists of an array of 3840 TESs coupled to X-ray absorbers and read out in the MHz bandwidth using Frequency Domain Multiplexing (FDM) based on Superconducting QUantum Interference Devices (SQUIDs). The proposed design calls for devices with a high filling-factor, high quantum efficiency, relatively high count-rate capability and an energy resolution of 2.5 eV at 5.9 keV. The paper will review the basic principle and the physics of the TES-based microcalorimeters and present the state-of-the art of the FDM read-out.
Similar papers
Transition-Edge Sensors for cryogenic X-ray imaging spectrometers
similarity 0.88Luciano Gottardi & Stephen Smith · 2022 · arXiv:2210.06617
Source status unknown — claims are unverified
Development of TES-based detectors array for the X-ray Integral Field Unit (X-IFU) on the future x-ray observatory ATHENA
similarity 0.88Luciano Gottardi et al. · 2016 · arXiv:1604.00553
Source status unknown — claims are unverified
Characterisation of a TES-Based X-ray Microcalorimeter in the Energy Range from 150 to 1800 eV Using an Adiabatic Demagnetisation Refrigerator
similarity 0.87Luciano Gottardi et al. · 2016 · arXiv:1604.02535
Source status unknown — claims are unverified
A Review of X-ray Microcalorimeters Based on Superconducting Transition Edge Sensors for Astrophysics and Particle Physics
similarity 0.87Luciano Gottardi & Kenichiro Nagayoshi · 2022 · arXiv:2210.06914
Source status unknown — claims are unverified
Hard X-ray Fluorescence measurements with TESs at the Advanced Photon Source
similarity 0.87Tejas Guruswamy et al. · 2019 · arXiv:1909.05919
Source status unknown — claims are unverified
Dark counts in optical superconducting transition-edge sensors for rare-event searches
similarity 0.87Laura Manenti et al. · 2024 · arXiv:2402.03073
Source status unknown — claims are unverified