A modular, extendible and field-tolerant multichannel vector magnetometer based on current sensor SQUIDs
Jan-Hendrik Storm, Dietmar Drung, Martin Burghoff, Rainer Körber
arXiv:1708.08382 · DOI 10.1088/0953-2048/29/9/094001 · 2017-08-28 · Superconductor Science and Technology
Active bibliographic source — not scientific approval
Bibliographic access preserves source history; it does not approve extracted materials or validate reported claims. Review warnings on each occurrence separately.
Abstract
We present the prototype module of our extendible and robust multichannel SQUID magnetometer system. A multi-module arrangement can be implemented by using up to 7 modules. It is intended for high-precision measurements of biomagnetism and spin precession. Further demanding applications are magnetorelaxometry and ultra-low-field nuclear magnetic resonance (ULF NMR), where pulsed fields of up to 100 mT are typically applied. The system is operated inside the Berlin Magnetically Shielded Room and equipped with 18 magnetometers consisting of niobium (Nb) wire-wound pick-up coils. A total of 16 small pick-up coils with 17.1 mm diameter form a regular grid with individual channels arranged to ensure system sensitivity covers all three orthogonal spatial directions. Two large hexagonal pick-up coils with an equivalent diameter of 74.5 mm sensitive in z-direction surround the grid at two different heights and are suitable for the detection of deep sources. Each coil is connected to the input of a thin-film Nb SQUID current sensor via a detachable superconducting contact. The SQUIDs are equipped with integrated input current limiters. Feedback into the pick-up coils minimizes crosstalk between channels. The current sensor chip package includes a superconducting shield of Nb. The field distortion of the prototype and a multi-module arrangement was analysed by numerical simulation. The measured noise of the small magnetometers was between 0.6 and 1.5 fT/Hz$^{1/2}$, and well below 1 fT/Hz$^{1/2}$ for the large ones. Using a software gradiometer, we achieved a minimum noise level of 0.54 fT/Hz$^{1/2}$. We performed ULF NMR experiments, verifying the system's robustness against pulsed fields, and magnetoencephalographgy (MEG) on somatosensory evoked neuronal activity. The low noise performance of our 18-channel prototype enabled the detection of high-frequency components at around 1 kHz by MEG.
Similar papers
SQUID-based interferometric accelerometer
similarity 0.87Ilia Khomchenko et al. · 2021 · arXiv:2108.11448
Source status unknown — claims are unverified
Ultra-sensitive SQUID systems for pulsed fields - Degaussing superconducting pick-up coils
similarity 0.87Eva Al-Dabbagh et al. · 2018 · arXiv:1801.07500
Source status unknown — claims are unverified
A micro-SQUID with dispersive readout for magnetic scanning microscopy
similarity 0.87Farshad Foroughi et al. · 2018 · arXiv:1803.07636
Source status unknown — claims are unverified
Flux ramp modulation based MHz frequency-division dc-SQUID multiplexer
similarity 0.86Daniel Richter et al. · 2021 · arXiv:2101.06424
Source status unknown — claims are unverified
SQUID current sensors with an integrated thermally actuated input current limiter
similarity 0.86Rainer Körber et al. · 2023 · arXiv:2302.13821
Source status unknown — claims are unverified
The role of kinetic inductance on the performance of YBCO SQUID magnetometers
similarity 0.86Ruffieux, S. et al. · 2020 · arXiv:1910.03991
Source status unknown — claims are unverified